2023
DOI: 10.3390/s23094317
|View full text |Cite
|
Sign up to set email alerts
|

Vehicle-Mounted Solar Occultation Flux Fourier Transform Infrared Spectrometer and Its Remote Sensing Application

Abstract: For the demand of rapid monitoring of pollution gas disorganized emissions in industrial parks, this paper studies the solar fast tracker system of vehicle-mounted SOF-FTIR (Solar Occultation Flux Fourier Transform Infrared Spectroscopy) system, where the spectrometer directly measures the broadband absorption spectrum of solar radiation light. A fast portable solar tracking system based on PSD (position sensitive detector) is designed, the mathematical model of solar spot position on the PSD surface source is… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
5
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
3

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(5 citation statements)
references
References 9 publications
0
5
0
Order By: Relevance
“…Thus, FCM can be a better choice than K-means and GF for KF to identify the LOS signals. Also, FT can calculate the frequency of data values [35,36], so FT can identify the long-term stable signal to retrieve stable LOS signals. BLE is supported by most mobile devices, and BLE utilizes low-energy signals which are very sensitive to distance differences [2,14].…”
Section: Related Workmentioning
confidence: 99%
See 3 more Smart Citations
“…Thus, FCM can be a better choice than K-means and GF for KF to identify the LOS signals. Also, FT can calculate the frequency of data values [35,36], so FT can identify the long-term stable signal to retrieve stable LOS signals. BLE is supported by most mobile devices, and BLE utilizes low-energy signals which are very sensitive to distance differences [2,14].…”
Section: Related Workmentioning
confidence: 99%
“…Then, KF moves to the next time interval and uses the new sample value to calculate the prediction value again. Usually, the system error, Q, is set to 0.1 and the measurement error, R, is set to 0.01 [35]. FFK does not use the fixed values but uses the initial 100 RSSI values, which reflect major error offsets, to calculate them, in order to obtain better prediction results.…”
Section: Fourier-transform Fuzzy C-means Kalman Filter Based Rssi Fil...mentioning
confidence: 99%
See 2 more Smart Citations
“…Sulfur hexafluoride has multiple characteristic peaks at 900-1600 cm −1 , and sulfur hexafluoride leakage detection can be carried out through these characteristic peaks [5]. In order to adapt to practical needs, portable FTSs, such as handheld [6,7] and vehicle-mounted [8] FTSs, have emerged. The interferometer is the core component of an FTS, and the miniaturization of the interferometer is the key to its portability [9].…”
Section: Introductionmentioning
confidence: 99%