2006
DOI: 10.1016/j.ijms.2006.01.030
|View full text |Cite
|
Sign up to set email alerts
|

Velocity map imaging mass spectrometry

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
7
0

Year Published

2007
2007
2014
2014

Publication Types

Select...
9

Relationship

1
8

Authors

Journals

citations
Cited by 12 publications
(7 citation statements)
references
References 21 publications
0
7
0
Order By: Relevance
“…However, in microscope‐mode imaging the trajectories of the analyte ions have to be controlled, which severely limits the range of techniques that can be used to increase the mass resolution of an experiment. Methods common to microprobe‐mode MS, such as the use of reflectrons, or ion cyclotron resonance instrumentation, allow for mass resolution ( m /Δ m 50 % ) of the order of 10 5 , but have not been shown to be compatible with microscope‐mode imaging; however, Suits and co‐workers have shown well‐resolved velocity‐mapped images (those associated with the back‐focal plane of the imaging system) using an instrument with a single‐stage reflectron implying that spatial imaging should be possible . It has also been shown that electrostatic analysers (ESAs) can be used to improve focusing in the time domain while retaining spatial information in microscope mode.…”
mentioning
confidence: 99%
“…However, in microscope‐mode imaging the trajectories of the analyte ions have to be controlled, which severely limits the range of techniques that can be used to increase the mass resolution of an experiment. Methods common to microprobe‐mode MS, such as the use of reflectrons, or ion cyclotron resonance instrumentation, allow for mass resolution ( m /Δ m 50 % ) of the order of 10 5 , but have not been shown to be compatible with microscope‐mode imaging; however, Suits and co‐workers have shown well‐resolved velocity‐mapped images (those associated with the back‐focal plane of the imaging system) using an instrument with a single‐stage reflectron implying that spatial imaging should be possible . It has also been shown that electrostatic analysers (ESAs) can be used to improve focusing in the time domain while retaining spatial information in microscope mode.…”
mentioning
confidence: 99%
“…The experimental apparatus used in this work was an adapted conventional velocity-map [7] ion imaging [8] instrument. The apparatus has been described in detail previously, both with [9] and without [10,11] the fast-framing camera, and only the most recent modifications to the apparatus shall be described here.…”
Section: Methodsmentioning
confidence: 99%
“…14,31 To enhance detection efficiency, mass resolving power and mass accuracy of MS, various technologies (in ionisation methods, mass analysers and detectors) have been developed for different applications and for use in multi-MS platforms. 14,[40][41][42][43] In plant metabolomic analyses, MS is the key platform for compound identification, an essential step in the workflow of any metabolomic analysis. The mass spectral data provides a pattern that is most often compound specific.…”
Section: And Weckwerth and Morgenthal 32mentioning
confidence: 99%