Verification of Indicated Skin Entrance Air Kerma for Cardiac X-Ray-Guided Intervention Using Gafchromic Film

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
7
0

Year Published

2020
2020
2022
2022

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 7 publications
(7 citation statements)
references
References 8 publications
0
7
0
Order By: Relevance
“…For patient studies with DoseMap [13] [16], em.dose [14] [15] and SkinCare [11], which included between 10 and 86 procedures, the result ranges were considerably larger than observed during simulated procedures in the present study. The absolute maximum deviation, however, was comparable for em.dose [14] [15] and SkinCare [11] Table 5: comparison of skin dose mapping (SDM) software results with existing literature.…”
Section: Comparison With Literaturementioning
confidence: 60%
See 1 more Smart Citation
“…For patient studies with DoseMap [13] [16], em.dose [14] [15] and SkinCare [11], which included between 10 and 86 procedures, the result ranges were considerably larger than observed during simulated procedures in the present study. The absolute maximum deviation, however, was comparable for em.dose [14] [15] and SkinCare [11] Table 5: comparison of skin dose mapping (SDM) software results with existing literature.…”
Section: Comparison With Literaturementioning
confidence: 60%
“…Various studies have compared skin dose measurements with SDM software. Some studies included real clinical cases [11,[13][14][15][16] while others used physical phantoms [8,10,15,[17][18][19]. The dosimetric capabilities and accuracy of the SDM products could strongly differ depending on the irradiation settings and the interventional X-ray system tested.…”
Section: Introductionmentioning
confidence: 99%
“…In modern x-ray systems, an estimate of the spatial distribution of the entrance surface air kerma (ESAK) is also available, taking into account the position of the patient relative to the x-ray source, the projection angle, the dose rate and the x-ray spectrum. However, previous studies have shown that skin dose estimates can differ significantly from the measured peak skin dose (3,4) .…”
Section: Introductionmentioning
confidence: 92%
“…CareMonitor by Siemens and DoseWise by Philips are solutions which basically provide the accumulated peak air kerma in the current projection 3 . On the other hand, Dose Map from GE is an advanced two‐dimensional (2D) solution, 4–6 while Dose Tracking System (DTS) from Canon (Toshiba) represents a state of the art three‐dimensional (3D) solution for skin dose mapping 7–9 . The most important drawback of previously mentioned solutions is that they are vendor specific and cannot be used in fluoroscopy systems from other manufacturers.…”
Section: Introductionmentioning
confidence: 99%