2017
DOI: 10.1016/j.jfoodeng.2016.08.002
|View full text |Cite
|
Sign up to set email alerts
|

Verification of radio frequency pasteurization process for in-shell almonds

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

3
29
0

Year Published

2018
2018
2022
2022

Publication Types

Select...
4
2
1

Relationship

1
6

Authors

Journals

citations
Cited by 96 publications
(32 citation statements)
references
References 32 publications
3
29
0
Order By: Relevance
“…For electrode gaps of 12.0, 14.0 and 16.0 cm, the corresponding time increased to 10, 15 and 20 min, thus raising the sample temperature from 20 to 80 °C; RF heating rate was above 4 °C min −1 in this study. Similar to the earlier work, heating rate and corresponding time changed with a change in the electrode gaps …”
Section: Resultssupporting
confidence: 55%
See 2 more Smart Citations
“…For electrode gaps of 12.0, 14.0 and 16.0 cm, the corresponding time increased to 10, 15 and 20 min, thus raising the sample temperature from 20 to 80 °C; RF heating rate was above 4 °C min −1 in this study. Similar to the earlier work, heating rate and corresponding time changed with a change in the electrode gaps …”
Section: Resultssupporting
confidence: 55%
“…Five distribution temperatures were averaged for quality control. According to previous work, an electrode gap of 10.5 cm was recommended for pasteurization, whereas an electrode gap of 12 cm was for drying . To avoid experimental failure, each pasteurization temperature was limited to 80 °C in this work.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…In the food processing industry, cold plasma treatment represents an innovative technology, especially since it has been proven to be effective against foodborne pathogens with relatively little effect on food nutritional value [25]. Yong et al [26] reported that the populations of E. coli, S. Typhimurium, and L. monocytogenes on cheese slices treated with plasma for 5 min (approximately 5 log CFU/g) were decreased by 1.75, 1.97, and 1.65 log CFU/g, respectively.…”
Section: Discussionmentioning
confidence: 99%
“…For example, IR has been used to inactivate Salmonella in almonds [15]. RF heating has ability for pasteurising Salmonella in almonds [16] and Salmonella and Escherichia coli O157: H7 on black and red pepper spices [17]. MW is used for inactivating Escherichia coli O157:H7, Salmonella Typhimurium and Listeria monocytogenes in salsa [18].…”
Section: Introductionmentioning