Verification of the James Webb Space Telescope Integrated Science Instrument Module cryogenic structural alignment requirements via photogrammetry

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
5
0

Year Published

2009
2009
2023
2023

Publication Types

Select...
4
2

Relationship

1
5

Authors

Journals

citations
Cited by 6 publications
(5 citation statements)
references
References 0 publications
0
5
0
Order By: Relevance
“…** They each have their advantages and disadvantages, as outlined elsewhere by Ohl et al (2009) [17]. Building on the work of Nowak et al (2007Nowak et al ( , 2008, pre-integration characterization of ISIM's PG system is complete. Recent ISIM mock-up testing included a "blind" survey, where PG targets were perturbed various distances on the structure and the system measured the resulting change.…”
Section: Ambient Metrologymentioning
confidence: 98%
See 1 more Smart Citation
“…** They each have their advantages and disadvantages, as outlined elsewhere by Ohl et al (2009) [17]. Building on the work of Nowak et al (2007Nowak et al ( , 2008, pre-integration characterization of ISIM's PG system is complete. Recent ISIM mock-up testing included a "blind" survey, where PG targets were perturbed various distances on the structure and the system measured the resulting change.…”
Section: Ambient Metrologymentioning
confidence: 98%
“…The KMs are thus stressed in a manner different from the flight condition and the corresponding A-to-B alignment change with temperature is different as when ISIM is mounted to the flight BSF. The cryogenic performance of the ITP will be characterized using the photogrammetry system (PG) [10,11]. The structure and KMs, attached to the ITP, will be characterized using PG for both an unloaded and loaded structure (SI mass models).…”
Section: Alignment Plan Updatesmentioning
confidence: 99%
“…12 Photogrammetry (PG) is used for cryogenic metrology of the ITP and ISIM structure (Figure 25b). 13 Cryogenic characterization of the ITP was completed in early 2010. The ITP dimensional change from ambient to cryogenic temperatures is in good agreement with model expectations.…”
Section: Custom Javascript Language Extensionsmentioning
confidence: 99%
“…In addition, photogrammetry targets can be readily related to the targets used for ambient surveys of the structure. Although photogrammetry systems have long been used in similar measurement scenarios [9,10], techniques for high-precision deformation measurements in vacuum environments are not yet mature. The OMT of the CSST requires a deformation resolution of more than 10 µm in a vacuum environment, which poses a challenge in terms of both the photogrammetry systems and the measurement methods used.…”
Section: Introductionmentioning