2022
DOI: 10.17085/apm.21065
|View full text |Cite
|
Sign up to set email alerts
|

Verification of the performance of the Bispectral Index as a hypnotic depth indicator during dexmedetomidine sedation

Abstract: Background: Differences in the effects of propofol and dexmedetomidine sedation on electroencephalogram patterns have been reported previously. However, the reliability of the Bispectral Index (BIS) value for assessing the sedation caused by dexmedetomidine remains debatable. The purpose of this study is to evaluate the correlation between the BIS value and the Modified Observer’s Assessment of Alertness/Sedation (MOAA/S) scale in patients sedated with dexmedetomidine. Methods: Forty-two patients (age range, 2… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

1
3
0

Year Published

2022
2022
2023
2023

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 9 publications
(4 citation statements)
references
References 27 publications
1
3
0
Order By: Relevance
“…We demonstrated the utility of BIS monitoring for assessing the level of sedation in patients undergoing FB. In accordance with previous reports, 4 , 10 , 14 the BIS value correlated with the clinically observed sedation scales. In this study, the correlation was stronger in patients under sufficient sedation (MOAA/S ≤ 4) than in all patients.…”
Section: Discussionsupporting
confidence: 92%
“…We demonstrated the utility of BIS monitoring for assessing the level of sedation in patients undergoing FB. In accordance with previous reports, 4 , 10 , 14 the BIS value correlated with the clinically observed sedation scales. In this study, the correlation was stronger in patients under sufficient sedation (MOAA/S ≤ 4) than in all patients.…”
Section: Discussionsupporting
confidence: 92%
“…The BIS value has been validated during sedation with dexmedetomidine. 57 The SPI value has been widely used for several years and has been reported to be more valid than other nociceptive monitors, such as the pupillary pain index and nociception level (NoL). 58 , 59 As expected, the BIS and SPI values of patients receiving OFA were within acceptable ranges.…”
Section: Discussionmentioning
confidence: 99%
“…A receiver operating characteristic (ROC) curve analysis was performed to estimate the performance of EEG parameters at specific sedation levels, referring to previous studies. 18,19 A state in which the MOAA/S score is greater than or equal to a specific score is defined as an event of "MOAA/S ≥ n," where n = 1, 2, 3, 4, and 5. The ROC curves for "MOAA/S ≥ n" were plotted for each EEG parameter, and the area under the ROC curves (AUROC) was estimated.…”
Section: Discussionmentioning
confidence: 99%