Versatile 3D‐Printed Micro‐Reference Electrodes for Aqueous and Non‐Aqueous Solutions

Abstract: While numerous reference electrodes suitable for aqueous electrolytes exist, there is no well-defined standardfor non-aqueous electrolytes.F urthermore,r eference electrodes are often large and do not meet the sizerequirements for small cells.Inthis work, we present asimple method for fabricating stable 3D-printed micro-reference electrodes.T he prints are made from polyvinylidene fluoride,w hich is chemically inert in strong acids,b ases,a nd commonly used non-aqueous solvents.W ec hose six different referenc… Show more

Help me understand this report
View preprint versions

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
8
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 7 publications
(8 citation statements)
references
References 55 publications
0
8
0
Order By: Relevance
“…The reference electrode, which is a self‐made 1 m Cu/CuCl 2 micro‐reference electrode, is placed from the side and the Au(111) single crystal can be dipped from atop, forming a hanging meniscus. The whole setup is installed in a glass tube with screwable caps for the top and bottom to reduce contaminations during the measurement [42] . The aqueous measurement was carried out using an SP‐300 Potentiostat from BioLogic and the same cell outside of the glovebox.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…The reference electrode, which is a self‐made 1 m Cu/CuCl 2 micro‐reference electrode, is placed from the side and the Au(111) single crystal can be dipped from atop, forming a hanging meniscus. The whole setup is installed in a glass tube with screwable caps for the top and bottom to reduce contaminations during the measurement [42] . The aqueous measurement was carried out using an SP‐300 Potentiostat from BioLogic and the same cell outside of the glovebox.…”
Section: Methodsmentioning
confidence: 99%
“…The whole setup is installed in a glass tube with screwable caps for the top and bottom to reduce contaminations during the measurement. [42] The aqueous measurement was carried out using an SP-300 Potentiostat from BioLogic and the same cell outside of the glovebox. The electrolyte and the glass tube containing the cell were purged with N 2 for 1 h before the measurement to get rid of O 2 in the system.…”
Section: Electrochemical Cellsmentioning
confidence: 99%
“…99 Schuett et al offered a straightforward approach for fabricating 3D-printed micro-reference electrodes (Figure 4b). 100 The chemically…”
Section: Miniaturization Of Screening Devicesmentioning
confidence: 99%
“…99 Schuett et al offered a straightforward approach for fabricating 3D-printed micro-reference electrodes (Figure 4b). 100 The chemically resistant polyvinylidene fluoride was used to 3D print the micro-reference electrodes (REs), which have an outer diameter of 4 mm and a length of 40 mm. The electrodes are sealed with a magnesia stick to ensure sealing.…”
Section: Short Review Synthesismentioning
confidence: 99%
See 1 more Smart Citation