2018
DOI: 10.3390/s18124493
|View full text |Cite
|
Sign up to set email alerts
|

Versatile Protein-A Coated Photoelectric Immunosensors with a Purple-Membrane Monolayer Transducer Fabricated by Affinity-Immobilization on a Graphene-Oxide Complexed Linker and by Shear Flow

Abstract: Bacteriorhodopsin-embedded purple membranes (PM) have been demonstrated to be a sensitive photoelectric transducer for microbial detection. To efficiently prepare versatile BR-based immunosensors with protein A as antibody captures, a large, high-coverage, and uniformly oriented PM monolayer was fabricated on an electrode as an effective foundation for protein A conjugation through bis-NHS esters, by first affinity-coating biotinylated PM on an aminated surface using a complex of oxidized avidin and graphene o… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

2
18
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
5

Relationship

3
2

Authors

Journals

citations
Cited by 6 publications
(32 citation statements)
references
References 41 publications
2
18
0
Order By: Relevance
“…ITO glass electrodes were coated with b-PM monolayers, which are termed b-PM chips, and were prepared as previously described [ 24 ]. APPA-aminated ITO glass was drop-coated with a GO-OA complex linker, which was prepared by mixing GO and OA at a 1:10 weight ratio, and then 1.5 mg/mL b-PM (coating diameter: 3 mm) and was subsequently washed with a laminar shear flow (Reynolds number = 0.9) inside a microfluidic setup.…”
Section: Methodsmentioning
confidence: 99%
See 4 more Smart Citations
“…ITO glass electrodes were coated with b-PM monolayers, which are termed b-PM chips, and were prepared as previously described [ 24 ]. APPA-aminated ITO glass was drop-coated with a GO-OA complex linker, which was prepared by mixing GO and OA at a 1:10 weight ratio, and then 1.5 mg/mL b-PM (coating diameter: 3 mm) and was subsequently washed with a laminar shear flow (Reynolds number = 0.9) inside a microfluidic setup.…”
Section: Methodsmentioning
confidence: 99%
“…This method of detection is verified using a BR-based Hb immunosensor that is prepared with a versatile protein A-conjugated PM electrode that was developed by the authors [ 24 ]. Two other aptasensors are devised by covalently attaching HbA0 and HbA1c-specific nucleic acid aptamers [ 18 ] on PM electrodes to, respectively, quantify HbA0 and HbA1c.…”
Section: Introductionmentioning
confidence: 99%
See 3 more Smart Citations