2014
DOI: 10.1002/elps.201300293
|View full text |Cite
|
Sign up to set email alerts
|

Very fast electrophoretic determination of creatinine and uric acid in human urine using a combination of two capillaries with different internal diameters

Abstract: A capillary system formed by combining 25 and 100 μm id capillaries was used in the short-end injection mode to determine creatinine and uric acid in human urine. The separation was performed at an electric field intensity of 2.3 kV/cm. Creatinine was determined in a BGE with a composition of 20 mM citric acid/NaOH (pH 3.0), and uric acid was determined in 20 mM MES/NaOH (pH 6.0). Under these conditions, migration times of 12.2 s for creatinine and 8.6 s for uric acid were achieved. The LOD value is 2.4 mg/L f… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
23
0

Year Published

2015
2015
2022
2022

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 33 publications
(23 citation statements)
references
References 29 publications
0
23
0
Order By: Relevance
“…Therefore, the Jaffe assay has been widely replaced by enzymatic methods [16]. In addition to enzymatic methods, numerous creatinine assays have been developed, such as high performance liquid chromatography (HPLC) [17], capillary electrophoresis [18], isotope-dilution mass spectrometry (IDMS) [19], tandem mass spectrometry [20], flow injection analysis [21], sequential injection analysis systems [22], microfluidic systems [23], zone fluidic multichannel kinetic spectrophotometry [24], surfaceenhanced Raman spectroscopy [25] and antibody-based sensors [26]. However, these methods are not commonly used in general laboratoriesbecause they require expensive instruments and are cumbersome for routine use [17,19].…”
Section: Introductionmentioning
confidence: 99%
“…Therefore, the Jaffe assay has been widely replaced by enzymatic methods [16]. In addition to enzymatic methods, numerous creatinine assays have been developed, such as high performance liquid chromatography (HPLC) [17], capillary electrophoresis [18], isotope-dilution mass spectrometry (IDMS) [19], tandem mass spectrometry [20], flow injection analysis [21], sequential injection analysis systems [22], microfluidic systems [23], zone fluidic multichannel kinetic spectrophotometry [24], surfaceenhanced Raman spectroscopy [25] and antibody-based sensors [26]. However, these methods are not commonly used in general laboratoriesbecause they require expensive instruments and are cumbersome for routine use [17,19].…”
Section: Introductionmentioning
confidence: 99%
“…The technique of joining two capillaries with different internal diameters developed by Pavlíček et al . was used to prepare connected capillaries.…”
Section: Methodsmentioning
confidence: 99%
“…In this test, alkaline picrate reacts with creatinine to form an orange-red product that is measured spectrophotometrically. Other current methods include HPLC-MS/MS [2], HPLC-DAD [3,4], spectrophotometry [5], spectrophotometry using a portable microfluidic system [6], and electrophoresis with electrochemical [7], UV [8], and colorimetric detection [9].…”
Section: Introductionmentioning
confidence: 99%