Very high pacing thresholds during long‐term follow‐up predicted by a combination of implant pacing threshold and impedance in leadless transcatheter pacemakers

Abstract: Background Micra transcatheter pacemaker system (TPS) usually achieves low implant pacing threshold (IPT). However, IPT may increase in some patients during follow‐up. Aim To apply implant parameters in predicting long‐term occurrence of very high pacing threshold (VHPT) in patients with Micra‐TPS. Methods A cohort of 110 consecutive patients implanted with a Micra‐TPS from 2014 to 2018 was evaluated at discharge and at 1, 12, 24, 36, and 48 months follow‐up. VHPT was defined as greater than 2 V/0.24 ms. VHPT … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

1
24
0
1

Year Published

2020
2020
2024
2024

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 24 publications
(26 citation statements)
references
References 13 publications
1
24
0
1
Order By: Relevance
“…While it was expected that impedance at the time of implantation would function as a predictive factor for the altered threshold status, it was also observed that the pacing threshold at the time of implantation served as a predictor in which it tended to be low if the device was well anchored. This finding is similar to a report by Tolosana et al, who showed that impedance and threshold at the time of implantation play important roles in achieving a pacing threshold of ≤2.0 V/0.24 ms 7 …”
Section: Discussionsupporting
confidence: 92%
See 3 more Smart Citations
“…While it was expected that impedance at the time of implantation would function as a predictive factor for the altered threshold status, it was also observed that the pacing threshold at the time of implantation served as a predictor in which it tended to be low if the device was well anchored. This finding is similar to a report by Tolosana et al, who showed that impedance and threshold at the time of implantation play important roles in achieving a pacing threshold of ≤2.0 V/0.24 ms 7 …”
Section: Discussionsupporting
confidence: 92%
“…This finding is similar to a report by Tolosana et al, who showed that impedance and threshold at the time of implantation play important roles in achieving a pacing threshold of ≤2.0 V/0.24 ms. 7 We observed that the pacing threshold improved in the majority of cases in the IPT group, while a higher threshold was maintained in a few cases. This may be due to fixation and adhesion of the dislodged device.…”
Section: Discussionmentioning
confidence: 55%
See 2 more Smart Citations
“…In Micra patients with an IPT of >1 to 2 V, approximately three‐quarters or more had an optimal threshold (≤1 V) by 6 months. However, if the IPT is ≥2 V, clinicians should strongly consider recapturing and redeploying the device, since an IPT of >2V was associated with VHPT in almost half of the patients at 6 months 49 . IPT ≤0.5 V/0.24 ms ensured a stable threshold during follow‐up.…”
Section: Introductionmentioning
confidence: 99%