Virtual clinical trial of lesion detection in digital mammography and digital breast tomosynthesis

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
61
0

Year Published

2018
2018
2021
2021

Publication Types

Select...
6
1

Relationship

2
5

Authors

Journals

citations
Cited by 40 publications
(62 citation statements)
references
References 31 publications
1
61
0
Order By: Relevance
“…Therefore, our approach for VCT schemes allows the rapid estimation of scatter fields in less than 20 s with errors of 3% within most of the area of the synthetic ( P + S ) image. By contrast, we note that in certain VCT schemes, scattered radiation is sometimes ignored …”
Section: Discussionmentioning
confidence: 94%
“…Therefore, our approach for VCT schemes allows the rapid estimation of scatter fields in less than 20 s with errors of 3% within most of the area of the synthetic ( P + S ) image. By contrast, we note that in certain VCT schemes, scattered radiation is sometimes ignored …”
Section: Discussionmentioning
confidence: 94%
“…Monte Carlo (MC) methods provide a gold‐standard approach to simulating noisy x‐ray projections. Recent works showed that a MC‐based method, as well as the single iteration x‐ray tracing used here, are capable of reproducing the outcome of real‐life DBT clinical trial using exclusively artificial data. However, even though both methods perform with an acceptable degree of realism, the computational time required by MC‐based methods is up to 65 times higher than required by the algorithm adopted here .…”
Section: Resultsmentioning
confidence: 99%
“…One of the earliest applications of VCTs was in the area of breast imaging for investigations of image quality, dosimetry, optimization, and technology evaluation. 30,213,[278][279][280][281][282][283][284][285][286][287][288][289] Recent VCTs have attempted to predict the ranking and the magnitude of improvement of breast imaging technologies as seen by human observers. 26,278,[290][291][292] In one example, VCTs were used in the Optimam project to evaluate the smallest detectable diameter of various lesions, showing that digital breast tomosynthesis (DBT) is superior to digital mammography (DM) for masses, 290 while the converse is true for calcifications.…”
Section: Breast Imagingmentioning
confidence: 99%
“…Researchers at the US Food and Drug Administration (FDA) compared the performance of DBT and DM with predicate premarket approval data for masses and calcifications based on differences in AUC. 26 In further work, Bakic et al 213 compared the performance of DBT and DM in the detection of calcifications and masses, simulating the Hologic Selenia Dimensions under clinically realistic conditions. The results of the VCT were compared with data reported by Rafferty et al 293 To compare differences in AUC, the VCT performance was calibrated to the predicted DM results; the DBT results were calculated for matching conditions.…”
Section: Breast Imagingmentioning
confidence: 99%