“…Such LOD is lower than the LOD of 0.2 ng mL -1 for IgE with fluorescent detection using an immunoprobe labelled with AuNCs [30]. Also, it compares favorably with most recently published methods for IgE determination in human serum (see Table 2) [30][31][32][33][34][35][36][37][38]. With ICP-MS detection of platinum, the linear range (IC20-IC80) extended from 0.10 ng mL -1 up to 2.6 ng mL -1 of IgE.…”
Section: Immunoassays For Ige Determination With Fluorescence and Icpmentioning
confidence: 65%
See 1 more Smart Citation
“…Such LOD is lower than the LOD of 0.2 ng mL -1 for IgE with fluorescent detection using an immunoprobe labelled with AuNCs [30]. Also, it compares favorably with most recently published methods for IgE determination in human serum (see Table 2) [30][31][32][33][34][35][36][37][38]. With ICP-MS detection of platinum, the linear range (IC20-IC80) extended from 0.10 ng mL -1 up to 2.6 ng mL -1 of IgE.…”
Section: Immunoassays For Ige Determination With Fluorescence and Icpmentioning
confidence: 65%
“…There are no conflicts to declare. CdS nanospheres and AuNPs Electrochemiluminescence aptasensor 0.02 [36] Aptamer modified with AgNPs Visual microarray 20 [37] Polystyrene and super-paramagnetic particle complexes…”
Section: Conflict Of Interestmentioning
confidence: 99%
“…In colorimetric detections, nanoparticles are also frequently used as reporting agents including silver [102], gold [103,104] and carbon nanoparticles [105] and aptamer-labeled bacteriophages [106]. Aptamer-modified silver nanoparticles were used for rapid, visual IgE detection, where anti-human IgE antibodies were spotted on solid support to capture IgE and form antibody/IgE/aptamer-AgNP complex.…”
Section: Ige Detection With Aptamersmentioning
confidence: 99%
“…The method was able to detect IgE down to ca. 20 ng/mL (105 pM) in a cost effective, easy-to-use manner [102].…”
Section: Ige Detection With Aptamersmentioning
confidence: 99%
“…A number of studies have reported the electrochemical sensing of IgE [4][5][6][7][8][9][10][11][12][13][14][15][16], with C, Pt, and Au being employed as electrode materials for the screen-printed electrochemical transducers used in allergen detection. Subsequent modification and functionalization of these materials was therefore aimed at promoting faster charge transfer, the stable attachment of bioreceptors, and enhancing the loading capacity of biomolecules.…”
Section: Introductionmentioning