2012
DOI: 10.1007/s00062-012-0136-3
|View full text |Cite|
|
Sign up to set email alerts
|

Visualisation of the Zona Incerta for Deep Brain Stimulation at 3.0 Tesla

Abstract: The delineation of the rZI is best possible in T2*-FLASH2D (particularly coronal view) using a standard installation protocol at 3.0 T. The caudal ZI could not be discerned in any of the sequences.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

1
22
1

Year Published

2013
2013
2020
2020

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 19 publications
(24 citation statements)
references
References 63 publications
1
22
1
Order By: Relevance
“…In addition, inconsistencies in the efficacy and adverse effects of ZI stimulation exist and likely reflect the inability to directly target the ZI resulting in variability of contact placement [20-23, 31, 32]. Methods for visualization of the rZI allowing direct stereotactic targeting have recently been reported [33, 34]. In addition, intraoperative microelectrode recordings may aide in direct targeting of the ZI as this region reveals a low amplitude background and a sparse cell density, as well as a lack of proprioceptive responses, which help to distinguish it from surrounding areas [24].…”
Section: Discussionmentioning
confidence: 99%
“…In addition, inconsistencies in the efficacy and adverse effects of ZI stimulation exist and likely reflect the inability to directly target the ZI resulting in variability of contact placement [20-23, 31, 32]. Methods for visualization of the rZI allowing direct stereotactic targeting have recently been reported [33, 34]. In addition, intraoperative microelectrode recordings may aide in direct targeting of the ZI as this region reveals a low amplitude background and a sparse cell density, as well as a lack of proprioceptive responses, which help to distinguish it from surrounding areas [24].…”
Section: Discussionmentioning
confidence: 99%
“…In the era of 1.5 T the direct visualization failed, secondary to insufficient contrast and low resolution [27,53] . At 3.0 T initial promis- ing results for the visualization of the ZI have been presented [54] . The implementation of 7.0 T MRI is a further technical advance to a higher signal and a superior spatial resolution compared to 1.5 T and 3.0 T [27,37,55] .…”
Section: Discussionmentioning
confidence: 99%
“…[5][6][7] However, in SPGR, clear depiction of midbrain necessitates a relatively long TE and, thus, results in long scan time. In this study, we propose the iDESS sequence which contains three innovative parts.…”
Section: Discussionmentioning
confidence: 99%
“…4 To achieve accurate diagnosis of movement disorders, previous studies used MRI to investigate the midbrain region, which is speculated to play an important role in related neurodegenerative diseases. 5,6 In addition to clinical diagnosis, MRI is also used in surgical planning of deep brain stimulation (DBS) in Parkinson's disease. [7][8][9][10] Conventionally, T2-and T2*-weighted MRI can be used to image midbrain nuclei because iron deposition in the brain is paramagnetic and leads to shortened T2 and T2*.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation