2020
DOI: 10.1049/iet-gtd.2020.0213
|View full text |Cite
|
Sign up to set email alerts
|

Voltage control using smart transformer via dynamic optimal setpoints and limit tolerance in a residential distribution network with PV sources

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
5
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
9

Relationship

1
8

Authors

Journals

citations
Cited by 17 publications
(5 citation statements)
references
References 22 publications
0
5
0
Order By: Relevance
“…1(a). For this the power flow solution is obtained considering ST LVAC terminal i.e., bus 1 as slack bus and remaining buses are considered as load buses [28]. The ST based meshed hybrid distribution network is a 16-bus system as shown in Fig.…”
Section: Proposed Power Flow Solution Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…1(a). For this the power flow solution is obtained considering ST LVAC terminal i.e., bus 1 as slack bus and remaining buses are considered as load buses [28]. The ST based meshed hybrid distribution network is a 16-bus system as shown in Fig.…”
Section: Proposed Power Flow Solution Methodsmentioning
confidence: 99%
“…The average voltage deviation index (V ad ) is considered along with the worst maximum and minimum bus voltages (V wmin and V wmax ) [28] to know the voltage profile of the system. The V ad is determined using ( 21)…”
Section: ) Voltage Profilementioning
confidence: 99%
“…Its primary winding is connected to the high-voltage power grid, and the secondary winding is connected to protection devices, measuring instruments, metering devices, and other equipment. It is used to convert the high voltage signal of the primary side into the low voltage signal of the secondary side for the safe collection of the secondary side protection, measurement and control, and metering equipment [2][3].…”
Section: Introductionmentioning
confidence: 99%
“…The connection of the PV panel to the main grid impacts the voltage stability of the system and leads to disturbances [ 9 ]. Therefore, several solutions have been introduced to mitigate the impact of penetrating the main grid [ 10 ], such as a meter data management system [ 11 ], smart transformers [ 12 ], smart inverters [ 13 ], an outage management system [ 14 ], and solar irradiance prediction [ 15 ]. Both grid-tied and off-grid PV systems can be improved if information about the future values of solar irradiance is accurately predicted [ 16 ].…”
Section: Introductionmentioning
confidence: 99%