2013
DOI: 10.1016/j.fusengdes.2013.02.071
|View full text |Cite
|
Sign up to set email alerts
|

Voltage holding optimization of the MITICA electrostatic accelerator

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
12
0

Year Published

2013
2013
2020
2020

Publication Types

Select...
5
1

Relationship

5
1

Authors

Journals

citations
Cited by 14 publications
(13 citation statements)
references
References 6 publications
1
12
0
Order By: Relevance
“…In the CAesium Test Stand (CATS) 11 the characterisation of the caesium ovens before installation into SPIDER and MITICA is performed, in terms of diagnostics, oven maintenance and caesium management. The High Voltage Padova Test Facility (HVPTF) 40 aims at performing optimised experiments of voltage holding up to 1MV in vacuum and with gas, with tight control of voltage, current, pressure and vacuum quality. The Negative Ion Optimisation facility, phase 1 (NIO1) 41 , is a versatile multiaperture hydrogen source, with compact and modular design, capable of continuous operation to reproduce the physics conditions of much larger ion sources, so as to readily verify the effects of individual source components/parameters and to compare results with simulations.…”
Section: Accompanying Facilitiesmentioning
confidence: 99%
“…In the CAesium Test Stand (CATS) 11 the characterisation of the caesium ovens before installation into SPIDER and MITICA is performed, in terms of diagnostics, oven maintenance and caesium management. The High Voltage Padova Test Facility (HVPTF) 40 aims at performing optimised experiments of voltage holding up to 1MV in vacuum and with gas, with tight control of voltage, current, pressure and vacuum quality. The Negative Ion Optimisation facility, phase 1 (NIO1) 41 , is a versatile multiaperture hydrogen source, with compact and modular design, capable of continuous operation to reproduce the physics conditions of much larger ion sources, so as to readily verify the effects of individual source components/parameters and to compare results with simulations.…”
Section: Accompanying Facilitiesmentioning
confidence: 99%
“…In the CAesium Test Stand (CATS) [25] the characterisation of the caesium ovens before installation into SPIDER and MITICA is performed, in terms of diagnostics, oven maintenance and caesium management [26]. The High Voltage Padova Test Facility (HVPTF) [27] aims at performing optimised experiments of voltage holding up to 1MV in vacuum and with gas, with tight control of voltage, current, pressure and vacuum quality.…”
Section: Accompanying Programmementioning
confidence: 99%
“…-An enhanced design has been developed for high voltage holding capability, by accelerator geometry optimization [58], in relation to the presence of low pressure gas, complex geometrical constraints and magnetic field, single and multiple gaps [59].…”
Section: The Mitica Beam Sourcementioning
confidence: 99%
“…Other achievements regard the validation of the Voltage Holding Predictive Model (VHPM), which allows the prediction of the voltage breakdown probability curve for any multivoltage-multielectrode configuration [96,97]. The VHPM has been applied in the design of the MITICA accelerator [58].…”
Section: High Voltage Padova Test Facilitymentioning
confidence: 99%