2020
DOI: 10.1049/iet-gtd.2019.1496
|View full text |Cite
|
Sign up to set email alerts
|

Voltage sag influence on controlled three‐phase grid‐connected inverters according to the Spanish grid code

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
9
0

Year Published

2020
2020
2022
2022

Publication Types

Select...
5
1

Relationship

1
5

Authors

Journals

citations
Cited by 10 publications
(9 citation statements)
references
References 35 publications
0
9
0
Order By: Relevance
“…where v abc Ref are the abc components of the reference voltage of the inverter, v g abc are the abc components of the grid voltage, i abc are the injected abc currents from the inverter to the grid and R and L are the resistance and the inductance of the filter, respectively. The authors' previous work [36,37] demonstrated the behaviour of grid-connected converter under grid faults according to the Spanish grid code. The reference positivetransformed currents are imposed directly from grid code by using Equation (2).…”
Section: Impact Of Dg Penetration On the Ds Protectionmentioning
confidence: 99%
See 1 more Smart Citation
“…where v abc Ref are the abc components of the reference voltage of the inverter, v g abc are the abc components of the grid voltage, i abc are the injected abc currents from the inverter to the grid and R and L are the resistance and the inductance of the filter, respectively. The authors' previous work [36,37] demonstrated the behaviour of grid-connected converter under grid faults according to the Spanish grid code. The reference positivetransformed currents are imposed directly from grid code by using Equation (2).…”
Section: Impact Of Dg Penetration On the Ds Protectionmentioning
confidence: 99%
“…The authors’ previous work [36, 37] demonstrated the behaviour of grid‐connected converter under grid faults according to the Spanish grid code. The reference positive‐transformed currents are imposed directly from grid code by using Equation (2).…”
Section: Impact Of Dg Penetration On the Ds Protectionmentioning
confidence: 99%
“…Regarding grid-connected inverters operating under unbalanced voltage conditions, the most common approach is to use a dual current control (DCC) in order to control both positive-and negative-sequence currents [9]. Moreover, current grid codes may also be used in order to inject reactive current for voltage support during grid faults [10], [11].…”
Section: Introductionmentioning
confidence: 99%
“…The current research efforts in the field of grid codes are focused on compliance tests for different control methods [4,5,6,7] and grid code reviews [8,9] in order to summarize the requirements of several TSOs. Additionally, some researchers focus on market-oriented grid codes studies [10], particularly, the impact of ancillary services provision and retribution strategies to secure the necessary amount of support to ensure grid stability during disturbances, and the various methods to incentivise WPPs.…”
Section: Introductionmentioning
confidence: 99%