Volume measurements of28Si-enriched spheres using an improved optical interferometer for the determination of the Avogadro constant

Abstract: For the determination of the Avogadro constant by the x-ray crystal density method, an accurate volume measurement of 1 kg Si spheres is of primary importance. For this purpose, an optical interferometer was improved and used to measure the volumes of two 1 kg silicon spheres which were manufactured from a silicon crystal highly enriched in 28 Si. The apparent volumes of the spheres, which do not take into account the influence of the surface layers on the volume measurement by interferometry, were determined … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
44
0

Year Published

2017
2017
2025
2025

Publication Types

Select...
4
2

Relationship

2
4

Authors

Journals

citations
Cited by 22 publications
(44 citation statements)
references
References 24 publications
0
44
0
Order By: Relevance
“…In a set of diameter measurements, the diameter is measured from 145 directions distributed near-uniformly on the sphere surface. 19 The set of diameter measurements is repeated, and between the sets, the for AVO28-S5c and 2.2 × 10 −8 for AVO28-S8c. 19 A different type of optical interferometer developed at the Physikalisch-Technische Bundesanstalt (PTB, Germany) was also used to measure the volume of AVO28-S5c…”
Section: Analytical Sciencesmentioning
confidence: 99%
“…In a set of diameter measurements, the diameter is measured from 145 directions distributed near-uniformly on the sphere surface. 19 The set of diameter measurements is repeated, and between the sets, the for AVO28-S5c and 2.2 × 10 −8 for AVO28-S8c. 19 A different type of optical interferometer developed at the Physikalisch-Technische Bundesanstalt (PTB, Germany) was also used to measure the volume of AVO28-S5c…”
Section: Analytical Sciencesmentioning
confidence: 99%
“…In a set of the diameter measurement, the diameter was measured from 145 directions distributed near-uniformly on the sphere surface [12,15]. The set of the diameter measurement was repeated 15 times.…”
Section: Optical Interferometrymentioning
confidence: 99%
“…The mean residual of the fitting was used as the uncertainty in the interferogram analysis [15]. Because this is a random uncertainty due to the noise in the interferogram, the uncertainty contributions from this source in 2015 and 2017 are not correlated.…”
Section: Si Core Volumementioning
confidence: 99%
See 2 more Smart Citations