Warning sign: toxic vessel reaction to an absorbable polymer-based paclitaxel-eluting stent in pig coronary arteries

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2

Citation Types

0
21
0

Year Published

2008
2008
2015
2015

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 12 publications
(21 citation statements)
references
References 0 publications
0
21
0
Order By: Relevance
“…This makes the CoCr stent to have the same mechanical stability with thinner stent struts to result in less tissue coverage, greater stent flexibility in curved lesions, and a more filigree design [33]. Results of a porcine model over 4 weeks clearly showed that using the Co-Cr stent as a base for DES instead of the 316L stainless steel stent, the achieved anti-inflammatory effect of the drug-loaded stent is consistently more than for the 316L stainless steel [31,[34][35][36][37]. For this study, the average inflammation score was 0.45 AE 0.42 for D1, D2 and D3 groups, indicating only mild intimal inflammation in the segment implanted with all five groups.…”
Section: Discussionmentioning
confidence: 87%
“…This makes the CoCr stent to have the same mechanical stability with thinner stent struts to result in less tissue coverage, greater stent flexibility in curved lesions, and a more filigree design [33]. Results of a porcine model over 4 weeks clearly showed that using the Co-Cr stent as a base for DES instead of the 316L stainless steel stent, the achieved anti-inflammatory effect of the drug-loaded stent is consistently more than for the 316L stainless steel [31,[34][35][36][37]. For this study, the average inflammation score was 0.45 AE 0.42 for D1, D2 and D3 groups, indicating only mild intimal inflammation in the segment implanted with all five groups.…”
Section: Discussionmentioning
confidence: 87%
“…Therefore, the Co-Cr stent is able to maintain the same mechanical stability with much thinner stent struts, which results in greater stent flexibility in curved lesions, and a more filigree design 20 . Results of a porcine model over 4 weeks clearly showed that using the CoCr stent as a base for DES instead of the 316L stainless steel, the achieved anti-inflammatory effect of the drug-loaded stent is consistently more 3, 12, 13, 17, 43 . For this study, the mild intimal inflammation responses observed in both CES and BMS groups, an even in the pure polymer coated stent group, were due to the use of the Co-Cr stent.…”
Section: Discussionmentioning
confidence: 98%
“…The long-term consequence of media necrosis in the pig model was evidenced in earlier study [29]. It has been demonstrated that loss of SMC could lead to late stent malapposition.…”
Section: In Vivo Studiesmentioning
confidence: 93%
“…Prior studies have examined novel polymer-free or absorbable polymer platforms for paclitaxel binding and delivery [29,31], but both these studies raised concerns with respect to paclitaxel toxicity. These findings not only reemphasized the narrow therapeutic window for eluted paclitaxel but also underscored the limited control of kinetic profiles and drug-loading capacity in the recent bioabsorbable-polymeric or non-polymeric approaches.…”
Section: In Vivo Studiesmentioning
confidence: 99%