2017
DOI: 10.1021/acs.jpcb.6b06822
|View full text |Cite
|
Sign up to set email alerts
|

Wavelength-Dependent Second Harmonic Generation Circular Dichroism for Differentiation of Col I and Col III Isoforms in Stromal Models of Ovarian Cancer Based on Intrinsic Chirality Differences

Abstract: Extensive remodeling of the extracellular matrix (ECM) occurs in many epithelial cancers. For example, in ovarian cancer, upregulation of collagen isoform type III has been linked to invasive forms of the disease, and this change may be a potential biomarker. To examine this possibility, we implemented wavelength-dependent second harmonic generation circular dichroism (SHG-CD) imaging microscopy to quantitatively determine changes in chirality in ECM models comprised of different Col I/Col III composition. In … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

2
46
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
4
2

Relationship

1
5

Authors

Journals

citations
Cited by 35 publications
(49 citation statements)
references
References 54 publications
2
46
0
Order By: Relevance
“…Imaging was performed with a fundamental laser wavelength of 890 nm for SHG forward-backward (F/B) and P-SHG analysis and 780 nm for SHG-CD; the shorter wavelength for the latter provides greater sensitivity. 5 Average powers at the focus were ∼30 to 50 mW using a 40× 0.8 NA water immersion lens (LUMPlanFL; Olympus, Tokyo, Japan) and a 0.9 NA condenser. The resulting lateral and axial resolutions were ∼0.7 and 2.5 μm, respectively.…”
Section: Shg Microscope Systemmentioning
confidence: 99%
See 4 more Smart Citations
“…Imaging was performed with a fundamental laser wavelength of 890 nm for SHG forward-backward (F/B) and P-SHG analysis and 780 nm for SHG-CD; the shorter wavelength for the latter provides greater sensitivity. 5 Average powers at the focus were ∼30 to 50 mW using a 40× 0.8 NA water immersion lens (LUMPlanFL; Olympus, Tokyo, Japan) and a 0.9 NA condenser. The resulting lateral and axial resolutions were ∼0.7 and 2.5 μm, respectively.…”
Section: Shg Microscope Systemmentioning
confidence: 99%
“…14 The linear and circular polarization states were validated as previously described by imaging cylindrically symmetric giant vesicles. 5,14 The polarization control was also run by a custom LabVIEW program interfaced to the FluoView scanning system.…”
Section: Shg Microscope Systemmentioning
confidence: 99%
See 3 more Smart Citations