2019
DOI: 10.1055/s-0039-1678531
|View full text |Cite
|
Sign up to set email alerts
|

Weight-Based Guide Overestimates Endotracheal Tube Tip Position in Extremely Preterm Infants

Abstract: Objective To evaluate the association between endotracheal tube (ETT) tip position and adverse pulmonary outcomes using chest X-ray (CXR) in extremely preterm infants in whom ETT insertion length was estimated using weight + 6 guide (adding 6 cms to the infant’s weight in kg). Study Design CXRs of 85 infants performed in the first week were reviewed for right-sided atelectasis, air leaks, and uneven lung inflation. The first CXR was later reviewed to document the ETT tip. Regression analysis was pe… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
7
0
1

Year Published

2020
2020
2024
2024

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 11 publications
(8 citation statements)
references
References 30 publications
(29 reference statements)
0
7
0
1
Order By: Relevance
“…However, CXR also has disadvantages, such as not giving instant information about the ETT tip, which can be malpositioned even when the baby turns his head. 10,12 In addition, the time elapsed between intubation and CXR interpretation may cause a late evaluation of placement. Also, radiation exposure is increased when CXRs are repeated.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…However, CXR also has disadvantages, such as not giving instant information about the ETT tip, which can be malpositioned even when the baby turns his head. 10,12 In addition, the time elapsed between intubation and CXR interpretation may cause a late evaluation of placement. Also, radiation exposure is increased when CXRs are repeated.…”
Section: Discussionmentioning
confidence: 99%
“…In CXR, the ETT tip placed between the first and third thoracic vertebra is classified as appropriate placement. However, CXR also has disadvantages, such as not giving instant information about the ETT tip, which can be malpositioned even when the baby turns his head 10,12 . In addition, the time elapsed between intubation and CXR interpretation may cause a late evaluation of placement.…”
Section: Discussionmentioning
confidence: 99%
“…Evidence summary: Malposition of the tracheal tube in infants can lead to life-threatening complications including hypo-xaemia, pneumothorax, and unintentional extubation 109,110 . A method for estimating appropriate insertion depth of a tracheal tube in neonates has been extensively studied (Supplementary Table S17, http://links.lww.com/EJA/A891).…”
Section: Methodsmentioning
confidence: 99%
“…Evidence summary: Malposition of the tracheal tube in infants can lead to life-threatening complications including hypo-xaemia, pneumothorax, and unintentional extubation. 109,110 A method for estimating appropriate insertion depth of a tracheal tube in neonates has been extensively studied (Supplementary Table S17, http:// links.lww.com/EJA/A891). Despite antero-posterior chest radiography considered as the gold standard for determining correct tracheal tube tip position, 106,111,112 there are limitations to this method, including lack of immediacy, no definite interpretation guidelines, and radiation exposure.…”
Section: Pico 5 Confirmation Of Tracheal Intubationmentioning
confidence: 99%
“…Es existieren Standardwerte für die Intubationstiefe nach Gestationsalter und Geburtsgewicht [4]. Allerdings lassen Standardwerte individuelle anatomische Unterschiede außer Acht, weshalb sie nur als Richtwerte dienen können und keine radiologische Lagekontrolle ersetzen [5].…”
Section: Introductionunclassified