2021
DOI: 10.1016/j.medengphy.2021.10.013
|View full text |Cite
|
Sign up to set email alerts
|

What do masks mask? A study on transdermal CO2 monitoring

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
3
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 6 publications
(8 citation statements)
references
References 38 publications
0
3
0
Order By: Relevance
“…This variation among individuals precludes the measurement of absolute tcpCO by mean of a rate-based approach without further improvements of the technique, as demonstrated by several authors who could only report trend analyses of skin CO exhalation rate, and no rate-based absolute tcpCO readings [ 319 , 321 , 322 ]. Further still, the recent work of Iitani et al [ 320 ] clearly illustrates the afore-mentioned inter-subject variability with a factor of more than ten between the exhalation rates of two subjects (S2 and S6 on their Figure 4-H). There may be an exception concerning neonates, however, whose exceedingly thin skin may be more homogeneous than that of adults, leading to less variability in their skin CO exhalation rate, and allowing Chatterjee et al [ 317 ] to demonstrate a significant correlation between skin CO exhalation rate and tcpCO .…”
Section: Future Applications To Transcutaneous Monitoringmentioning
confidence: 73%
See 1 more Smart Citation
“…This variation among individuals precludes the measurement of absolute tcpCO by mean of a rate-based approach without further improvements of the technique, as demonstrated by several authors who could only report trend analyses of skin CO exhalation rate, and no rate-based absolute tcpCO readings [ 319 , 321 , 322 ]. Further still, the recent work of Iitani et al [ 320 ] clearly illustrates the afore-mentioned inter-subject variability with a factor of more than ten between the exhalation rates of two subjects (S2 and S6 on their Figure 4-H). There may be an exception concerning neonates, however, whose exceedingly thin skin may be more homogeneous than that of adults, leading to less variability in their skin CO exhalation rate, and allowing Chatterjee et al [ 317 ] to demonstrate a significant correlation between skin CO exhalation rate and tcpCO .…”
Section: Future Applications To Transcutaneous Monitoringmentioning
confidence: 73%
“…The NDIR track was then dropped until the mid-2010s and the advent of rate-based approaches by the team of Chatterjee, Ge, Iitani et al [ 317 , 318 , 319 , 320 ] at first and by the team of Grangeat et al [ 321 , 322 ] in a second move. If the latter work is insufficiently detailed—especially the explanations concerning the sensing part itself—the former allows for a sound understanding of the rate-based approach.…”
Section: Future Applications To Transcutaneous Monitoringmentioning
confidence: 99%
“…This type of flow pattern shows few perturbations and turbulence, and it is typical during normal breathing conditions. In our study, we developed a mathematical model described by Equation (10), where a and b are the rectangular aperture half-lengths and x and y are the base coordinates that define the two laminar profiles intersecting at v max (see Figure 1b). In the model, the velocity profile at entry falls from v max to zero at the internal wall surfaces.…”
Section: Mathematical Analysis Based On Laminar Flow Modelmentioning
confidence: 99%
“…Face masks have different filtration efficiency based on fiber size, morphology (random or ordered structure), pore size, and material weave. Furthermore, air flow velocity and breathing have an impact on filtration efficiency [7][8][9][10]. Therefore, researchers are investigating the fabrication of face masks with high filtration efficiency to decrease the spread of airborne diseases.…”
Section: Introductionmentioning
confidence: 99%
“…2(a)] similarly to in a previous paper. (21) The experimental protocol involved wearing a nonwoven mask for a predetermined period while working with the room temperature adjusted to 20 or 30 ℃, as shown in Fig. 2(b).…”
Section: Monitoring Intra-oral Temperature Using Mg Thermometermentioning
confidence: 99%