X-Ray Microscopy at Sirius, the New Brazilian Synchrotron Light Source

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
4
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
3
1

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(4 citation statements)
references
References 4 publications
0
4
0
Order By: Relevance
“…However, when a mixed state of misalignment takes place, the coefficients may be summed in a way that makes the identification of the misaligned DOF puzzling, if not impossible. For example, figure 4 shows that both Rx 1 and z 1 affect the same Zernike coefficients, j = (3,4,6), which creates an ambiguity. This is in accordance with the discussion in the previous section about the correction of misalignment of the longitudinal positioning with adjustments in the mirror's incidence angle.…”
Section: Zernike Polynomialsmentioning
confidence: 99%
See 1 more Smart Citation
“…However, when a mixed state of misalignment takes place, the coefficients may be summed in a way that makes the identification of the misaligned DOF puzzling, if not impossible. For example, figure 4 shows that both Rx 1 and z 1 affect the same Zernike coefficients, j = (3,4,6), which creates an ambiguity. This is in accordance with the discussion in the previous section about the correction of misalignment of the longitudinal positioning with adjustments in the mirror's incidence angle.…”
Section: Zernike Polynomialsmentioning
confidence: 99%
“…Because they are in general achromatic * and allow relatively large acceptance of the beam and working distance, they are the choice for nanofocusing optics at Sirius. 3,4 It is well known that the alignment and stability of these optical systems are critical for high-resolution experiments. The proper alignment of these optics can only be achieved if diagnostics of the X-ray beam aberrations are available with sufficient sensitivity.…”
Section: Introductionmentioning
confidence: 99%
“…It will also extend photon correlation techniques into the regime of nanoseconds (Khubbutdinov et al, 2019). The gain in coherent flux brought by the fourth-generation light sources allows experimental data to be obtained within a few seconds (Westfahl et al, 2018). Along with the development of the light source, high-frame-rate detectors are also widely used in synchrotron radiation experiments on beamlines.…”
Section: Introductionmentioning
confidence: 99%
“…Ptychography (Rodenburg et al, 2007;Thibault et al, 2008;Pfeiffer, 2018) has become the most versatile and promising coherent diffractive imaging (CDI) technique (Chapman et al, 2006), being a high-resolution scanning-type microscopy capable of imaging conceptually unbounded samples at diffraction-limited resolutions. Because of that, it has seen interest at several synchrotron facilities around the globe, including on the Carnau ´ba beamline (Tolentino et al, 2017(Tolentino et al, , 2019 currently under construction at the new fourthgeneration synchrotron source, Sirius, in Brazil (Rodrigues et al, 2019;Westfahl et al, 2018). This new source is currently under commissioning by the Brazilian Synchrotron Light Laboratory (LNLS), operated by the Brazilian Center for Research in Energy and Materials.…”
Section: Introductionmentioning
confidence: 99%