2016
DOI: 10.14233/ajchem.2016.19993
|View full text |Cite
|
Sign up to set email alerts
|

Zwitterionic Ion Chromatography of Dansyl Amino Acids with 4-Vinylbenzyl Dimethyl Ammonio Pentanesulfonate as Stationary Phase

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
11
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
7
1

Relationship

2
6

Authors

Journals

citations
Cited by 15 publications
(11 citation statements)
references
References 0 publications
0
11
0
Order By: Relevance
“…The stationary phases used for the separation of SBS were performed onto the PS/DVB, using PEEK columns (100 × 4 mm ID) by means of grafted sulfobetaine monomers. [13][14][15][16] HPLC grade of ACN was purchased from Aldrich (total 99.93 percent). The capacity of the ZIC1 and ZIC5 columns are 432 and 488 μeq g -1 , 10 respectively.…”
Section: Methodsmentioning
confidence: 99%
“…The stationary phases used for the separation of SBS were performed onto the PS/DVB, using PEEK columns (100 × 4 mm ID) by means of grafted sulfobetaine monomers. [13][14][15][16] HPLC grade of ACN was purchased from Aldrich (total 99.93 percent). The capacity of the ZIC1 and ZIC5 columns are 432 and 488 μeq g -1 , 10 respectively.…”
Section: Methodsmentioning
confidence: 99%
“…ZIC1 and ZIC5 were developed on the polystyrene-divinylbenzene (PS/DVB), by means of a grafted sulfobetaine monomer (100 × 4 mm ID) and PEEK column, for the 2-deoxycytidine separation. 5,[9][10][11] The systematic cycle of grafting reaction has been established by Raskop et al 20 Chemicals 2-deoxycytidine (HPLC) purchased by Sigma-Aldrich 99%. Acetic acid was purchased from BDH.…”
Section: Instrumentation and Chromatographic Conditionmentioning
confidence: 99%
“…4 HILIC's approach to several previously intimidating separation problems is currently strongly attracted. The analysis of pharmaceuticals, [5][6][7][8] dansyl amino acids, 9 inorganic anions, 10 carboxylic acid, 11 sugar, 12 and saccharides, 13 by the successful implementation of HILIC technology has been achieved. dCD (Figure 1) is a component of deoxyribonucleic acid, and deoxyribonucleoside.…”
Section: Introductionmentioning
confidence: 99%
“…Hydrophilic and polar compounds, as compared to hydrophobic neutral compounds, are retained preferentially in HILIC the contrary of RP-HPLC. Thus recently, HILIC technology has thus recently begun to increase dramatically in the estimation of drugs, nucleosides, carboxylic acids, inorganic ions, and amino acids by Rasheed and its co-workers [24][25][26][27][28][29][30][31][32][33][34]. Experimental…”
Section: Introductionmentioning
confidence: 99%