2020
DOI: 10.1016/j.renene.2020.02.091
|View full text |Cite
|
Sign up to set email alerts
|

Εnergy-exergy analysis of ultra-supercritical biomass-fuelled steam power plants for industrial CHP, district heating and cooling

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
9
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
6
2
1

Relationship

0
9

Authors

Journals

citations
Cited by 49 publications
(9 citation statements)
references
References 40 publications
0
9
0
Order By: Relevance
“…Several steam plant simulation studies do not declare which medium model they adopted for steam and water thermodynamics, but still ought to be mentioned. These simulation studies include ultra-critical biomass steam power plants [33], new industrial waste heat recovery systems with seasonal thermal storage [34], new waste heat DH systems with CHP [35], and optimization of coal-fired CHP to decouple heat and power modes [36]. In addition to Modelon's Thermal Power Library [30], there are numerous Modelica libraries suitable for steam plants, such as ClaRa+ [37] and ThermoSysPro [38].…”
Section: Literature Reviewmentioning
confidence: 99%
“…Several steam plant simulation studies do not declare which medium model they adopted for steam and water thermodynamics, but still ought to be mentioned. These simulation studies include ultra-critical biomass steam power plants [33], new industrial waste heat recovery systems with seasonal thermal storage [34], new waste heat DH systems with CHP [35], and optimization of coal-fired CHP to decouple heat and power modes [36]. In addition to Modelon's Thermal Power Library [30], there are numerous Modelica libraries suitable for steam plants, such as ClaRa+ [37] and ThermoSysPro [38].…”
Section: Literature Reviewmentioning
confidence: 99%
“…They also carried out an optimization of this system by the particle swarm optimization (PSO) algorithm. Braimakis et al [20] conducted an energy and exergy assessment of the ultra-supercritical biomass-fueled steam cycle. They performed sensitivity analyses for widespread ranges of heat demand.…”
Section: Introductionmentioning
confidence: 99%
“…Also, the impacts of reference temperature are determined for the temperature of the gasifier and solar radiation intensity. For direct heating and cooling for industrial applications, Braimkis et al [27] suggested an ultra-supercritical biomass-based steam power plant. Different senarios were considered in that research and it was found that in the power-only plan, the proposed plant's power and exergy efficiencies were higher than the CHP scenario that the heat demand was maximum.…”
Section: Introductionmentioning