The extent of bone remodelling under metal fixation plates attached to bone by (i) normal screw fixation and (ii) bone ingrowth into a porous metallic surface underlayer sintered to the metal plate was investigated. Extensive bone remodelling was observed under the integrally bonded porous surface layered plate. This remodelling could be attributed to the more extensive stress transfer from bone to metal plate because of the good bone-to-implant bonding. The importance of stress shielding with high stiffness implants is demonstrated.
Periprosthetic bone loss, which is a direct cause of aseptic loosening in total hip arthroplasty (THA), can be suppressed by bisphosphonates. It is unknown how the quality of this bone is affected in the presence of both wear debris (from implant) and bisphosphonates. The objective of this study was to evaluate the effect of zoledronate (ZLN) on bone quality in the presence of wear debris [polyethylene (PE) particles] in a canine model of uncemented THA. Thirty dogs underwent THA, and aseptic loosening was induced via implantation of PE particles packed into the femoral component. For 26 weeks until sacrifice, two groups (each n = 10) received weekly injections of ZLN (low dose 2 mug/kg, high dose 10 mug/kg) and the third group (control) received saline. Histological and radiographic examinations were performed to evaluate the degree of implant reaction. Histomorphometry (static/dynamic) was performed to evaluate bone turnover. Back-scattered electron imaging was used to quantify the newly formed bone and to evaluate the mineralization distribution. Density fractionation and X-ray diffraction were used to evaluate mineral properties, while four-point bending was used to determine mechanical properties. A dose-dependent presence of newly formed subperiosteal bone was found, which appeared to be less mineralized than the adjacent cortical bone. The high-dose ZLN group showed decreased cortical porosity and turnover and increased mineralization profile, failure strength, and modulus. We conclude that ZLN affects some of the material properties of cortical bone and allows the newly formed subperiosteal bone to remain and therefore affect the overall quality of the bone.
The purpose of this study was to determine the biological effects of the elastic modulus of the femoral stem in canine hip arthroplasty. Cementless total hip arthroplasty was performed in 12 dogs, six had a low elastic modulus polyacetal resin stem and six had a high modulus stainless steel stem. The components were otherwise similar. At six and 12 months after operation, radiographic and histomorphometric analysis showed that those with steel implants had more cortical porosity than did the other group (p less than 0.01). We suggest that the elastic modulus of the implant is an important factor in controlling cortical bone resorption. A low modulus femoral prosthesis can significantly decrease bone resorption which might otherwise eventually lead to implant failure.
Porous coated canine femoral hip replacement implants were evaluated for biological fixation by bone ingrowth and the effect of the extent of porous coating on bone modeling. The Co-Cr alloy implants were either fully porous coated or coated only on the proximal 40% of the stem. Two implants of each type were studied 9, 16, and 36 months after surgery. Implant fixation and bone modeling were assessed radiographically throughout the implant periods and histologically after the test animals were killed. All 12 implants appeared stably fixed within the femur and were bone-ingrown in the porous region. Radiographic features such as proximal medial and anterior cortical thinning, proximal cancellous bone hypertrophy, and new endosteal bone formation near the stem tip were noted within the first postoperative year, with no appreciable change thereafter. The extent of proximal cortical thinning varied from virtually none to as much as 40%, being more prominent with the proximally coated implants at 16 months and with the fully coated implants at 36 months. Of consistent note was cancellous hypertrophy at the junction of porous and smooth implant surfaces with proximally coated implants and new endosteal bone formation and ingrowth at the stem tip of fully coated implants. These results indicate that the proximally porous-coated implant design causes increased proximal stress transfer, but this does not necessarily preclude proximal cortical resorption.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.