Twenty five (25%) mediastinoscopies were positive and three were false-negative (3%). There were 29 false-positive CT scans and 12 false-negative. Overall sensitivity and specificity of CT were 63 and 57%, respectively, and of mediastinoscopy 89 and 100%, respectively. Positive and negative predictive values of CT were 41 and 77%, respectively, and of mediastinoscopy 100 and 96%, respectively. Accuracy of CT was 59% and of mediastinoscopy 97%. Accuracy of CT was lowest for left-sided and centrally located tumours, and for LN station 7.Even with current computed tomography scanners, sensitivity and specificity remain low. Although overall cost may increase, routine cervical mediastinoscopy is necessary for precise staging of non-small cell lung cancer, and subcarinal lymph nodes should be routinely sampled.
Even with present-day CT scanners (i)TNM provides no accurate staging and routine mediastinoscopy is necessary for precise mediastinal lymph node staging. Likewise, (i)T3 and (i)T4 determinations are unreliable and should not contraindicate thoracotomy.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.