Scatter reduction by air gaps in mammography was investigated. We have experimentally demonstrated that, independently of the imaging geometry, scatter in air-gap mammography can be well described by a virtual source of scatter (VSS) model. This model postulates that scatter radiation originates from a virtual point source of scatter placed on the central axis between the x-ray source and the exit surface of a patient at distance delta and utilizes only two parameters: delta and (S/P)0. The (S/P)0 parameter represents scatter-to-primary ratio without an air gap and delta is the distance from the exit surface of a patient to the virtual source of scatter. We have experimentally determined the analytical form of the two independent parameters of the VSS model; delta exhibits a linear increase proportional to the radiation field size, does not depend on patient thickness, and is in the 10-30 cm range, while (S/P)0 increases with the field size as a power function and is in the 0.4-1.3 range. In the framework of the VSS model the selectivity, the contrast improvement factor, and the signal-to-noise improvement factor were employed to evaluate performance of air-gap mammography systems. We have demonstrated that selectivity of an air gap rapidly deteriorates at some well-defined critical value of scatter fraction that has profound consequences on air-gap performance. Assuming fixed patient exposure, the results shows that, if a contrast limited detection system (such as film/screen mammography) is used, an air gap system can outperform a grid system only if a very large source-to-patient (SPD) distance is utilized, which might be possible with new laser-based x-ray sources. For the noise limited detection systems (such as digital mammography) even a small SPD (70 cm) and a small air-gap (20 cm) system will outperform a grid system.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.