Lung density patterns in a group of randomly selected, normal individuals were determined by computed tomography, using two methods: one measuring the density of the peripheral lung (parenchyma), and the other determining the density of the whole lung field. The effects of body position and respiratory phase, as well as patient age were assessed. The potential use for this information in clinical settings and in physiological investigation is suggested.
Interaction of intense Ti:sapphire laser with solid targets has been studied experimentally by measuring hard x-ray and hot electron generation. Hard x-ray ͑8 -100 keV͒ emission spectrum and K␣ x-ray conversion efficiency ͑ K ͒ from plasma have been studied as a function of laser intensity ͑10 17 -10 19 W/cm 2 ͒, pulse duration ͑70-400͒fs, and laser pulse fluence. For intensity I Ͼ 1 ϫ 10 17 W/cm 2 , the Ag K increases to reach a maximum value of 2 ϫ 10 −5 at an intensity I =4 ϫ 10 18 W/cm 2 . Hot electron temperature ͑KT h ͒ and K scaling laws have been studied as a function of the laser parameters. A stronger dependence of KT h and K as a function of the laser fluence than on pulse duration or laser intensity has been observed. The contribution of another nonlinear mechanism, besides resonance absorption, to hard x-ray enhancement has been demonstrated via hot electron angular distribution and particle-in-cell simulations.
A laser-produced plasma (LPP) x-ray source with possible application in mammography was created by focusing a laser beam on a Mo target. A Table-Top-Terawatt (TTT) laser operating at 1 J energy per pulse was employed. A dual pulse technique was used. Maximum energy transfer (approximately 10%) from laser light to hot electrons was reached at a 150 ps delay between pulses and the conversion efficiency (hard x-ray yield/laser energy input) was approximately 2 x 10(-4). The created LPP x-ray source is characterized by a very small focal spot size (tens of microns), Gaussian brightness distribution, and a very short pulse duration (a few ps). The spectral distribution of the generated x rays was measured. Images of the focal spot, using a pinhole camera, and images of a resolution pattern and a mammographic phantom were obtained. The LPP focal spot modulation transfer function for different magnification factors was calculated. We have shown that the LPP source in conjunction with a spherically bent, high throughput, crystal monochromator in a fixed-exit Rowland circle configuration can be used to created a narrow band tunable mammography system. Tunability to a specific patient breast tissue thickness and density would allow one to significantly improve contrast and resolution (exceeding 20 lp/mm) while lowering the exposure up to 50% for thicker breasts. The prospects for the LPP x-ray source for mammographic application are discussed.
Scatter reduction by air gaps in mammography was investigated. We have experimentally demonstrated that, independently of the imaging geometry, scatter in air-gap mammography can be well described by a virtual source of scatter (VSS) model. This model postulates that scatter radiation originates from a virtual point source of scatter placed on the central axis between the x-ray source and the exit surface of a patient at distance delta and utilizes only two parameters: delta and (S/P)0. The (S/P)0 parameter represents scatter-to-primary ratio without an air gap and delta is the distance from the exit surface of a patient to the virtual source of scatter. We have experimentally determined the analytical form of the two independent parameters of the VSS model; delta exhibits a linear increase proportional to the radiation field size, does not depend on patient thickness, and is in the 10-30 cm range, while (S/P)0 increases with the field size as a power function and is in the 0.4-1.3 range. In the framework of the VSS model the selectivity, the contrast improvement factor, and the signal-to-noise improvement factor were employed to evaluate performance of air-gap mammography systems. We have demonstrated that selectivity of an air gap rapidly deteriorates at some well-defined critical value of scatter fraction that has profound consequences on air-gap performance. Assuming fixed patient exposure, the results shows that, if a contrast limited detection system (such as film/screen mammography) is used, an air gap system can outperform a grid system only if a very large source-to-patient (SPD) distance is utilized, which might be possible with new laser-based x-ray sources. For the noise limited detection systems (such as digital mammography) even a small SPD (70 cm) and a small air-gap (20 cm) system will outperform a grid system.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.