Vibrated stone columns are frequently used as a method of reinforcing soft ground as they provide increased bearing capacity and reduce foundation settlements. Their performance in relation to bearing capacity is well documented, but there is also a need for enhanced understanding of their settlement characteristics, particularly in relation to small-group configurations. This paper presents results obtained from physical model tests on triaxial specimens 300 mm in diameter and 400 mm high. Parameters investigated include column length to diameter ratio, area replacement ratio and single/group configuration. The findings of the work are as follows. The design is flexible: settlement can equally be controlled using short columns at relatively high area replacement ratios, or longer columns at smaller area replacement ratios. An optimum area replacement ratio of 30-40% exists for the control of settlement. The settlement performance of a small column group is highly influenced by inter-column and footing interaction effects.
The vibrated stone column technique is an economical and environmentally friendly process that treats weak ground to enable it to withstand low to moderate loading conditions. The performance of the treated ground depends on various parameters such as the strengths of the in-situ and backfill materials, and the spacing, length and diameter of the columns. In practice, vibrated stone columns are frequently used for settlement control. Studies have shown that columns can fail by bulging, bending, punching or shearing. These failure mechanisms are examined in this paper. The study involved a series of laboratory model tests on a consolidated clay bed. The tests were carried out using two different materials: (a) transparent material with ‘clay like’ properties, and (b) speswhite kaolin. The tests on the transparent material have, probably for the first time, permitted visual examination of deforming granular columns during loading. They have shown that bulging was significant in long columns, whereas punching was prominent in shorter columns. The presence of the columns also greatly improved the load-carrying capacity of the soft clay bed. However, columns longer than about six times their diameter did not lead to further increases in the load-carrying capacity. This suggests that there is an optimum column length for a given arrangement of stone columns beneath a rigid footing.
The mechanism whereby foundation loading is transmitted through the column has received little attention from researchers. This paper reports on some interesting findings obtained from a laboratory-based model study in respect of this issue. The model tests were carried out on samples of soft clay, 300 mm in diameter and 400 mm high. The samples were reinforced with fully penetrating stone columns, of three different diameters, made of crushed basalt. Four pressure cells were located along each stone column. The 60 mm diameter footing used in the model was supported on a clay bed reinforced with a stone column and subjected to foundation loading under drained conditions. The results show that the dissipation of excess pore water pressure developed during the initial application of total stresses, when the foundation was subjected to no loading, generated considerable stresses within the column, and that this was directly attributable to the development of negative skin friction. The pressure distributions in the column during foundation loading showed some complex behaviour.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.