Failure of eruption of permanent molars is an uncommon condition with a range of possible causative factors. This retrospective study of 35 pediatric subjects assesses the influence of these factors in the prognosis. The study aims to broaden our understanding of an abnormality, which has a considerable clinical impact, and proposes a treatment protocol for the management of these patients.
The purpose of this study was to develop a technique to evaluate the implant-abutment gap of an external hexagon implant system as a function of radius. Six implants of 3.75 mm in diameter (Conexao Sistema de Protese Ltda, Sao Paulo, Brazil) and their respective abutments were screw connected and torqued to 20 N cm(-1). The implants were mounted in epoxy assuring an implant long-axis position perpendicular to the vertical axis. Each implant was grounded through its thickness parallel to implant long-axis at six different distance interval. Implant-abutment gap distances were recorded along the implant-abutment region for each section. Individual measurements were related to their radial position through trigonometric inferences. A sixth degree polynomial line fit approach determined radial adaptation patterns for each implant. Micrographs along implant sections showed a approximately 300 mum length implant-abutment engagement region. All implants presented communication between external and internal regions through connection gaps and inaccurate implant-abutment alignment. Average gap distances were not significantly different between implants (P > 0.086). Polynomial lines showed implant-abutment gap values below 10 mum from 0 mum to approximately 250 mum of the implant-abutment engagement region. Gap distances significantly increased from approximately 250 mum to the outer radius of the implant-abutment engagement region. The technique described provided a broader scenario of the implant-abutment gap adaptation compared with previous work concerning implant-abutment gap determination, and should be considered for better understanding mechanical aspects or biological effects of implant-abutment adaptation on peri-implant tissues.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.