Nutritional status must be monitored and managed before, during and after treatment. A variety of nutritional and tumor-related factors must be considered. According to our results, head and neck tumors and the use of chemotherapy are the only two factors considered statistically significant. Because patients continue to lose weight after treatment, we recommend close surveillance after radiotherapy.
A verification protocol (3-mm action level) provided by EPIDs improves the set-up accuracy. Intrafractional error is not negligible and contributes to create a larger CTV-PTV margin. The appropriate CTV-PTV margin for our institute is between 3 and 4.5 mm considering both inter- and intrafractional errors.
Objective
Lung CT scans are early diagnostic tests in evaluation of COVID-19 patients. Data are usually analyzed visually and the extent of infiltrations can only roughly be estimated. The aim of the present study was to create a software to spatially visualize and quantify infiltrated and collapsed areas in lung CT scans and set these volumes into relation with non-affected lung areas.
Methods
A new software "Lung CT Analyzer" (LCTA, 1) was created from scratch in an international team-effort within the 3D medical imaging software 3D Slicer (2). LCTA consists of two components: "Lung CT Segmenter" implements an intuitive and semiautomatic workflow for the generation of lung masks. LCTA then uses masked thresholds of Hounsfield units to detect non-affected versus affected (emphysematous, infiltrated, and collapsed) areas of the lung. Intrapulmonary vessels are subtracted from the other volumes. Segment volumes are expressed in milliliters and displayed in 3D. COVID-Q was defined as affected divided by non-affected volume and can be calculated separately for both lungs.
3D Slicer and LCTA are open source, freely available and maintained on Github.
Results
CT data of twelve patients with moderate to severe COVID-19 (9 m, 3 f) were selected for the present retrospective study. All scans were performed shortly after admission. Thresholds of Hounsfield units (HU) for areas of interest were defined prior to the study and processing was identical for all patients. The median time effort for 3D reconstruction was 8 minutes per patient. For more detailed results please see the enclosed table. A 3D Slicer demo data set (Control) has been included for comparison.
Conclusion
The COVID-19 pandemic promoted fast-paced innovations such as LCTA in our hospital. LCTA was feasible, reproducible and easy to perform. COVID-Q correlated with COVID-19 lung involvement in all cases. All fatal cases showed COVID-Q values of > 2.0.
LCTA enabled the serial 3D reconstruction of infiltrated and collapsed lung areas in lung CT scans. The procedure may be of great help in the future analysis of pulmonary infiltrates of any cause. In COVID-19 disease, volumetric lung CT reconstruction could result in the definition of new prognostic factors, identify patients “at-risk” in the ICU, and be useful for follow-up.
(1) Lung CT Analyzer: https://github.com/rbumm/SlicerLungCTAnalyzer
(2) 3D Slicer: http://slicer.org
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.