2021
DOI: 10.1093/bjs/znab202.077
|View full text |Cite
|
Sign up to set email alerts
|

First results of spatial reconstruction and quantification of COVID-19 chest CT infiltrates using lung CT analyzer and 3D slicer

Abstract: Objective Lung CT scans are early diagnostic tests in evaluation of COVID-19 patients. Data are usually analyzed visually and the extent of infiltrations can only roughly be estimated. The aim of the present study was to create a software to spatially visualize and quantify infiltrated and collapsed areas in lung CT scans and set these volumes into relation with non-affected lung areas. Methods A new software "Lung CT Analyze… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
9
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 10 publications
(9 citation statements)
references
References 0 publications
0
9
0
Order By: Relevance
“…Total segmented lobe volume was validated against total segmented lung volume. 3D Slicer was used to segment the COVID-19 affected GGO and consolidated regions of the lungs at end-inspiratory and end-expiratory phases using the LungCTAnalyzer [ 27 ] extension of the Chest Imaging Platform ( Fig. 1 b).…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…Total segmented lobe volume was validated against total segmented lung volume. 3D Slicer was used to segment the COVID-19 affected GGO and consolidated regions of the lungs at end-inspiratory and end-expiratory phases using the LungCTAnalyzer [ 27 ] extension of the Chest Imaging Platform ( Fig. 1 b).…”
Section: Methodsmentioning
confidence: 99%
“…Inflated lung Hounsfield unit thresholds were determined based on the study by Kassin et al [ 28 ] with a range of −1000 to −650 HU. The difference between ground glass opacities and consolidated regions were determined based on the 3D Slicer Chest Imaging Platform [ 24 ] and Lung CT Analyzer [ 27 ] ( https://github.com/rbumm/SlicerLungCTAnalyzer ) extensions preset values for COVID-19 lung analysis.
Fig.
…”
Section: Methodsmentioning
confidence: 99%
“…CT segmentation ran automatically with a high degree of retest reliability. 3D segmentations were made using an open-source tool, giving any research team the opportunity to conduct the same analysis (26).…”
Section: Discussionmentioning
confidence: 99%
“…A group blinded volumetric analysis and visualization in 3D Slicer (http://www.slicer.org) on hard kernel chest CT image reconstructions using the open-source Lung CT Analyzer project tool (https://github.com/rbumm/ SlicerLungCTAnalyzer/) was performed (26). The volumetric analysis proved robust for lung segmentation under the presence of severe pneumonia (see Figure 2A-2E) (26,27). The total 3D volume of each lung side was assessed (see Figure 2D) (26).…”
Section: Automated Segmentation Of the Lungs And Lung Pathologiesmentioning
confidence: 99%
See 1 more Smart Citation