EPR dosimetry is characterized by its non-destructive read-out and the possibility of dose archival. Here, taurine is proposed as a radiation dosimeter using EPR spectroscopy. The EPR spectrum of taurine was studied and assigned, and changes in the taurine EPR spectrum as a result of the change in both modulation amplitude and microwave power were quantified. For gamma radiation, the energy absorption coefficient and the collision mass stopping power of taurine were compared to the corresponding values of soft tissue and alanine, in addition to calculation of effective atomic numbers. The response of taurine to gamma radiation doses in the range from 0.1 to 50 kGy was investigated, as well as that in the range from 1.0 to 20.0 Gy using numerically enhanced EPR taurine spectra. Both response curves showed a linear behavior. In addition, the time dependence of radiation-induced radicals was studied for short (during the first 6 h after irradiation) and long (during about 3 months after irradiation) time periods, and a reasonable degree of stability of the taurine radicals was observed. It is concluded that taurine is a promising dosimeter, which is characterized by its simple spectrum, radical stability, and wide range of linear response to gamma radiation.
Tooth enamel samples from molar teeth of camel were prepared using a combined procedure of mechanical and chemical tooth treatment. Based on electron paramagnetic resonance (EPR) spectroscopy, the dose response of tooth enamel samples was examined and compared to that of human enamel. The EPR dose response of the tooth enamel samples was obtained through irradiation to gamma doses from 1 Gy up to 100 kGy. It was found that the radiation-induced EPR signal increased linearly with gamma dose for all studied tooth enamel samples, up to about 15 kGy. At higher doses, the dose response curve leveled off. The results revealed that the location of the native signal of camel tooth enamel was similar to that of enamel from human molars at 2.00644, but different from that of enamel from cows and goats. In addition, the peak-to-peak width (ΔH ) for human and camel molar teeth was similar. It was also found that the response of camel enamel to gamma radiation was 36% lower than that of human enamel. In conclusion, the results indicate the suitability of camel teeth for retrospective gamma dosimetry.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.