IntroductionAlthough known as a possible graft option for decades, quadriceps tendon grafts have often been termed a second-line graft option. We report a consecutive case series using this method as the primary treatment line. The rationale for this study was to evaluate the midterm results of this method in a prospective and consecutive case series. The primary study question was to determine the clinical results 24–36 months after primary anterior cruciate ligament (ACL) reconstruction using a bone plug-free quadriceps tendon autograft fixed with bioabsorbable cross-pins.Materials and methodsThe study population included 55 patients, of whom 24 were female (43.6%). The mean age at the index procedure was 31.7 years (15–58 years). All patients received an ACL construction using a bone block-free quadriceps tendon graft fixed with resorbable cross-pins. The postoperative regimen included partial weight-bearing for 3 weeks and flexion limited to 90° for six weeks; an orthosis was not used. The mean follow-up duration was 29.5 months (24.3–38.5 months) after the index procedure. The International Knee Documentation Committee (IKDC) subjective score and examination form was assessed, as well as the Lysholm and Gillquist score and the Tegner activity index. The Rolimeter arthrometer was used to assess the anterior laxity of the knee.ResultsGraft harvesting was possible in all cases; a bony extension was never required. On average, graft length was measured at 8.8 cm (7.5–10 cm). The mean IKDC subjective score at follow-up was 80.44 points (55.17–100 points, standard deviation [SD] 12.05). The mean preinjury Tegner activity index was 4.98 (2–7) compared to a mean value of 4.16 (2–7, SD 0.8) at follow-up. There was a mean loss of 0.82 index points. The average Lysholm and Gillquist score was 89 points (65–100, SD 17.7). Of the results, 89.1% were in the good or very good groups; in one case (1.8%), the result was poor, while the rest were fair.ConclusionACL reconstruction using a bone plug-free quadriceps tendon autograft achieved satisfactory results in a midterm review.
Overextension of filling material into the mandibular canal after root treatment in the lower jaw is a rare but serious complication. Mechanical compression, chemical neurotoxicity and local infection may cause irreversible nerve damage. A report on 11 patients with neurological complaints of the inferior alveolar nerve after endodontic treatment is summarised. The neurological findings are dominated by hypaesthesia and dysaesthesia. Half of the patients reported pain. Hyperaesthesia is found much more rarely. Nearly all the patients had a combination of one or more symptoms. Initial X-rays showed root filling material in the area of the mandibular canal. Nine cases were treated with apicectomy and decompression of the nerve; in two cases, extraction of the tooth was necessary. Only one patient reported persistent pain after surgery. If neurological complaints appear after root filling in the lower jaw, a nerve injury due to root filling material should be ruled out. In cases of overfilling, immediate apicectomy and decompression of the nerve with conservation of the tooth is often the treatment of choice; the tooth may be preserved and the best chance of avoiding permanent nerve damage is provided.
Purpose : The Direct Anterior Approach (DAA) is well established as a minimal access approach in elective orthopaedic hip surgery. For the growing number of elderly patients with femoral neck fractures treated with Bipolar Hip Hemiarthroplasty (BHH), only a few results do exist. The study shows the clinical and radiological outcome for 180 patients treated by a modified DAA with BHH.Materials and Methods : The data of 180 geriatric patients with medial femoral neck fractures were evaluated retrospectively. The general and surgical complications, mobilisation using the Timed Up and Go test (TUG), the social environment pre- and postoperative and the radiological results have been compared with established approaches for geriatric hip surgery.Results : After joint replacement, 18 (10%) patients were developed pneumonia, of which 3 (1.7%) died during hospitalisation. In 7 cases (4%), surgical revision had to be carried out: three times (1.7%) because of a seroma, three times (1.7%) because of subcutaneous infection, and one time (0.6%) because the BHH was removed, owing to deep wound infection. One dislocation (0.6%) occurred, as well as one femoral nerve lesion (0.6%) occured. 88.3% of patients were mobilised on walkers or crutches; the Timed Up and Go Test showed a significant improvement during inpatient rehabilitation. 83% were discharged to their usual social environment, 10% were transferred to a short-term care facility and 7% were relocated permanently to a nursing home. 3/4 of patients had a cemented stem alignment in the range between -5° and 5°, while 2/3 of patients had a maximum difference of 1 cm in leg length.Conclusion : Using the modified DAA, a high patient satisfaction is achieved after implantation of a BHH. The rate of major complications is just as low as in conventional approaches, and rapid mobilisation is possible.
Objectives: There is only sparse data on clinical results and complications of the third-generation Gamma nailing system (Gamma3, Stryker). Therefore, we started a large multi-centre case series in 2008. The aim of this paper is to present the study design and early results of a single arm of a prospective, consecutive, monitored, post-market follow-up evaluation of Gamma3 nails. Methods: From September 2009 to January 2012, 154 consecutive patients with an average age of 80 ± 1.43 years (50-99 years) and a trochanteric femoral fracture were included in the local arm of the trial. All patients that fulfilled the inclusion criteria were treated with a Gamma3 nail. Preoperative variables included age, gender, fracture classification, walking ability (Merle d’Aubigné score), daily activity level (retrospective Zuckerman score), ASA rating of operative risk, waiting time for operation, use of walker or crutches and body mass index (BMI). Skin-to-skin time, fluoroscopy time, blood loss, intraoperative complications and device information were recorded for each patient. Follow-up postoperative assessment was undertaken at 4, 12 and 24 months. Hip range of motion, pain around the hip and the tight, walking ability (Merle d’Aubigné score, Sahlgrenska mobility score) and management of daily life (Zuckerman score) were used to evaluate the outcome. Results: The descriptive data of age, gender, BMI, ASA classification, fracture type and skin-to-skin time is similar to other studies. Median fluoroscopy time was 62 seconds (range: 4-225 seconds) and significantly shorter in closed reductions. No intraoperative implant-related complication was recorded. A cut-out of the leg-screw during assessment period occurred in 2.6% patients (n = 4). At the 12-month assessment two (1.8%) non-unions were identified and two patients (1.8%) had broken the femoral shaft below the 180 mm nail after a fall. Analysis of the scores showed significantly declined mobility and activity in daily life four months after operation which increased significantly from four to 12 months and increased slightly between 12 and 24 months after fracture. Conclusion: A low implant-associated complication rate was achieved in geriatric patients with trochanteric femoral fractures using the Gamma3 nail. A better outcome concerning mobility, activity in daily life and complications compared to the Gamma2 nail could not be found in comparison to historic data.
The aim of this study was to investigate the accuracy of bone mineral density (BMD) determined by quantitative computed tomography (qCT) based on in situ and ex situ scans of cadavers of variable stature. The in uence of surrounding tissue on the quanti cation of CT images of ex situ scanned femora was investigated in air and in water and compared with the in situ scanned femora. The study showed that the surrounding tissue has an impact on the grey value-based representation of the scanned object as well as on the calibration of BMD, in uencing the determination of BMD. Local di erences in BMD of up to 17.5% were observed, which might originate from beam hardening artifacts.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.