Vascular grafts are devices intended to replace compromised arteries in the body and grafts made of polyethylene terephthalate (PET) fabric have been used mainly for synthetic grafting procedures involving medium to large diameter vascular grafts. Though porosity of the graft permits tissue in-growth, it would lead to bleeding through the graft walls immediately after implantation. So it is essential to seal the pores either by preclotting with patient's own blood or by other sealing materials prior to implantation in order to prevent blood leakage through the graft wall. Biodegradable hydrogel materials are ideal candidates for this purpose. Apart from sealing the pores, they offer biocompatible and low-thrombogenic surfaces when coated on vascular graft. In the present study, a biodegradable hydrogel, derived from oxidized alginate and gelatin, has been deposited on PET grafts by dip coating and were characterized for its efficacy on sealing the pores of the graft. Water permeability in the static and pulsatile conditions, burst strength, in vitro cell culture cytotoxicity, hemocompatibility, and endothelial cell adhesion and proliferation of the coated grafts were investigated. Results showed that the alginate dialdehyde cross-linked gelatin hydrogel was nontoxic, hemocompatible, and was efficient in sealing the pores of the graft. Blood perfusion study showed that when hydrogel-coated grafts were exposed to blood for 30 min, they showed little affinity toward platelets or leukocytes. Hemolytic potential of PET was significantly reduced when it was coated with hydrogel. Improved adhesion and proliferation of endothelial cells were observed when PET grafts were coated with hydrogel. Results also showed that coating with hydrogel did not affect the burst strength of the PET graft.
The bi-layer porous-dense HA buttons are useful in preventing cosmetic defects over burr-hole sites on the scalp after cranial neurosurgical procedures. It does not interfere with current radiological imaging methods in the postoperative phase.
Woven polyethylene terephthalate (PET) fabric has been used in the construction of vascular grafts and sewing ring of prosthetic heart valves. In an effort to improve haemocompatibility and tissue response to PET fabric, a fluoropolymer, polyvinylidine fluoride (PVDF), was coated on PET fabric by dip coating technique. The coating was found to be uniform and no significant changes occurred on physical properties such as water permeability and burst strength. Cell culture cytotoxicity studies showed that coated PET was non-cytotoxic to L929 fibroblast cell lines. In vitro studies revealed that coating improved haemocompatibility of PET fabric material. Coating reduced platelet consumption of PET fabric by 50%. Upon surface modification leukocyte consumption of PET was reduced by 24%. About 60% reduction in partial thromboplastin time (PTT) observed when PET was coated with PVDF. Results of endothelial cell proliferation studies showed that surface coating did not have any substantial impact on cell proliferation. Overall results indicate that coating has potential to improve haemocompatibility of PET fabric without affecting its mechanical performance.
Average age group of heart valve replacement in India and most of the Third World countries is below 30 years. Hence, the valve for such patients need to be designed to have a service life of 50 years or more which corresponds to 2000 million cycles of operation. The purpose of this study was to assess the structural performance of the TTK Chitra tilting disc heart valve model TC2 and thereby address its durability. The TC2 model tilting disc heart valves were assessed to evaluate the risks connected with potential structural failure modes. To be more specific, the studies covered the finite element analysis-based fatigue life prediction and accelerated durability testing of the tilting disc heart valves for nine different valve sizes. First, finite element analysis-based fatigue life prediction showed that all nine valve sizes were in the infinite life region. Second, accelerated durability test showed that all nine valve sizes remained functional for 400 million cycles under experimental conditions. The study ensures the continued function of TC2 model tilting disc heart valves over duration in excess of 50 years. The results imply that the TC2 model valve designs are structurally safe, reliable and durable.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.