Background Although open surgery remains the gold standard for the treatment of post-dissection thoraco-abdominal aneurysms (TAAAs), the endovascular approach using fenestrated or branched endografts has emerged as a valid alternative for patients considered at high risk for surgery. The use of inner branch devices (iBEVAR) combining benefits of fenestrations and outer branches could offer an ideal configuration in this context. Aims Our aim was to report our preliminary monocentric experience with iBEVAR in the treatment of post-dissection TAAAs. Methods A retrospective analysis of prospective data retrieved from 1 center between Mars 2020 and January 2023 was done. Endpoints were immediate technical success, postoperative morbidity, rate of endoleaks, re-intervention and mortality. Results During this period, 18 patients (mean age 66,5 years, range 41-80) were identified. All were asymptomatic and operated in a 2-steps procedure with a TEVAR first. There were 5 off-the-shelf E-nside (28%) and 13 custom-made Extra-Design grafts (72%). Despite successful endograft deployment in all patients and branch catheterization in 68/70 cases (97%), the technical success was 94% due to an open conversion for ilio-mesenteric bypass. The 30-days mortality was 0%. During the post-operative period, 17% of patients (3/18) presented complications with 1 case of mesenteric ischaemia requiring a visceral resection and 2 cases of paralytic ileus, treated conservatively. No spinal cord ischemia was observed. During the median follow-up of 16 months (range 1-36), 4 patients (22%) had a re-intervention: one case of type-Ic endoleak treated with an additional renal stent and 3 cases of type-III endoleaks in the celiac trunk requiring a relining. The overall target vessel patency was 100%. In all cases, the sac diameter remained stable. Conclusions The use of iBEVAR appears to be safe and effective for the treatment of post-dissection TAAAs with an acceptable rate of complications. Further patients and longer follow-up are needed.
Objective Endovascular repair (EVAR) has become the standard of care for treatment of abdominal aortic aneurysms. However, a significant number of EVAR remains outside the IFU, especially in cases of severe proximal angulation (>60 degrees), resulting in failure. The new device GORE EXCLUDER Conformable AAA Endoprosthesis (W. L. Gore & Associates, Flagstaff, Ariz) has been designed to accommodate neck angulation, due to conformability and angulation control. The aim of this multicenter study is to report the initial results of this device. Methods From March 2019 to January 2021, the data of all consecutive patients with AAA treated with the Gore Excluder Conformable endograft at 4 vascular centers were reviewed. Patients were followed using a standardized protocol, with CT-scan at 1, 6 and 12 months, and then yearly. The primary endpoint was technical success and secondary outcomes were postoperative morbidity, rate of endoleak (EL) and any aneurysm-related re-interventions during follow-up. Results Among the 32 patients included, most were men with a mean age of 77 years old (range 60-92). Half of patients were smokers and 72% had hypertension. The mean diameter of AAA was 62 mm (47-90). The mean length of aortic neck was 26 mm (10-69), the mean diameter 23 mm (16-31) and the median neck angulation was 81 degrees (range 40-110). The mean procedural duration was 102 min (54-153) with a mean time of scopy of 24 min (8-47) and a total volume of contrast of 101 ml (40-165). Thirteen iliac branch device have been used in 7 patients. The technical success was 97% with 1 type Ia EL (3%). In the post-operative period, 4 medical and 3 surgical complications were observed. Two reinterventions were needed with an iliac stenting for a stenosis and a correction of a femoral false aneurysm. During the mean follow-up of 7 months, 2 type Ia ELs were observed. One spontaneously resolved and the other one was followed. One distal limb extension was succesfully implanted at 3 months for a type Ib EL for a total rate of reintervention of 9%. No migration was observed. No death occured. Conclusion The use of the Gore Excluder Conformable endograft seems to be safe and effective in difficult anatomies and especially high angulation. It allows for precise deployment without the need for additional contrast or operation time. Longer follow-up and more patients are required to confirm these excellent initials results.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.