Background Although open surgery remains the gold standard for the treatment of post-dissection thoraco-abdominal aneurysms (TAAAs), the endovascular approach using fenestrated or branched endografts has emerged as a valid alternative for patients considered at high risk for surgery. The use of inner branch devices (iBEVAR) combining benefits of fenestrations and outer branches could offer an ideal configuration in this context. Aims Our aim was to report our preliminary monocentric experience with iBEVAR in the treatment of post-dissection TAAAs. Methods A retrospective analysis of prospective data retrieved from 1 center between Mars 2020 and January 2023 was done. Endpoints were immediate technical success, postoperative morbidity, rate of endoleaks, re-intervention and mortality. Results During this period, 18 patients (mean age 66,5 years, range 41-80) were identified. All were asymptomatic and operated in a 2-steps procedure with a TEVAR first. There were 5 off-the-shelf E-nside (28%) and 13 custom-made Extra-Design grafts (72%). Despite successful endograft deployment in all patients and branch catheterization in 68/70 cases (97%), the technical success was 94% due to an open conversion for ilio-mesenteric bypass. The 30-days mortality was 0%. During the post-operative period, 17% of patients (3/18) presented complications with 1 case of mesenteric ischaemia requiring a visceral resection and 2 cases of paralytic ileus, treated conservatively. No spinal cord ischemia was observed. During the median follow-up of 16 months (range 1-36), 4 patients (22%) had a re-intervention: one case of type-Ic endoleak treated with an additional renal stent and 3 cases of type-III endoleaks in the celiac trunk requiring a relining. The overall target vessel patency was 100%. In all cases, the sac diameter remained stable. Conclusions The use of iBEVAR appears to be safe and effective for the treatment of post-dissection TAAAs with an acceptable rate of complications. Further patients and longer follow-up are needed.
Objective In case of complex aortic aneurysmal disease, fenestrated or branched EVAR (b/f-EVAR) is considered as a valid and safe alternative to open surgery. However, one the main limitation is the time required for manufacture, limiting its use in emergent situations. The new off-the-shelf 4 inner branches E-nside (Jotec, Hechingen, Germany) has been developed to offer a solution in such circumstances. The aim of this study was to report our preliminary monocentric experience with this new device. Methods Retrospective analysis of prospective data retrieved from 1 center between November 2020 and January 2022 was done. Endpoints were technical success, postoperative morbidity, rate of endoleak and any aneurysm-related re-interventions during follow-up. Results In this study, 15 patients (mean age 73 years, range 59–90) were identified. There was a majority of male (9/15) and all of them but 3 were asymptomatic. The mean aneurysmal diameter was 60 mm (range 50–100). There were 3 cases of juxtarenal aortic aneurysms (20%), 1 Crawford type I (7%), 4 type II (27%), 4 type III (27%) and 3 type IV (20%) aneurysms. In 7 cases, a 2-steps procedure was done with a TEVAR first followed by Enside implantation. There was a technical success in 93% with 1 open conversion for a mesenterical bypass. There was no death in the post-operative period. During the post-operative period, 33% of patients (5/15) presented complications with 3 complications related to the femoral or iliac access and 2 cases of spinal cord ischemia (13%). One case occurred in an emergent setting of a type III aneurysm rupture. The other case was the open conversion and the patient also developed a colic ischemia and finally died 4 months alter. The mean length of stay was 9 days. During the follow-up, 2 reinterventions were necessary, 1 for a type Ic endoleak with distal prolongation of the stent and 1 renal stent occlusion treated by relining. The overall target vessel patency was 98%. Conclusion The use of the off-the-shelf 4 inner branches E-nside appears to be safe with good technical success for the treatment of complex aortic aneurysmal disease. It is associated with an acceptable rate of complications and allows for treatment of a wide variety of diseases in an emergent setting. Further patients and longer follow-up are required to better evaluate the exact role of this new device.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.