BackgroundContextual processing dysfunction in patients with schizophrenia (SCZ) is not uniform and task-dependent. In SCZ, studies on the rod and frame test (RFT), which evaluates contextual modulation of verticality perception, are sparse. A main study that utilized a two-alternative forced choice design for judging rod verticality reported equivalent strength of RFT contextual modulation in healthy controls and SCZ. The current study aims to uncover any potential differences in contextual modulation between controls and SCZ with an adjustment method on a computerized RFT.Materials and methodsA total of 17 healthy controls and 15 SCZ aligned an oriented rod to their perceived vertical with a computer mouse under four randomized frame presentations: absent frame, non-tilted (Frame0°), or tilted by 18 degrees leftward (Frame–18°) or rightward (Frame+18°). Rod deviation error was assigned a negative or positive value when aligned leftward or rightward, respectively, of 0°. Signed and absolute errors, the rod and frame effect (RFE), and intra-individual variability (inconsistency) were used for analysis.ResultsThere was no group difference in rod alignment errors or derived measures, except that SCZ displayed greater inconsistency in rod alignment, compared to controls. The negative symptom scale (PANSS-N) scores correlated positively with the variability measure and with unsigned Frame–18° error.ConclusionsOnly the variability measure was sensitive enough to distinguish between controls and SCZ. SCZ with more severe negative symptoms had larger variability in rod alignment, probably reflecting a state of indifference. The larger deviation errors only with a leftward tilted frame, as PANSS-N scores increased, may indicate a lateralized attentional abnormality that is correlated with severity of symptoms in SCZ.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.