Purpose: Estimate organs doses (ODs) of patients subjected to unenhanced (S1) and enhanced (S2) chest CT studies relying on image parameters such as Hounsfield Units (HUs). Materials and Methods: CT scans and images of a total of 16 patients who underwent two series of chest CT studies were obtained and retrospectively examined. OD increments of liver and pancreas for both series (S1 & S2) were estimated using two different independent methods, namely simulation approach using CT-EXPO and Amato’s phantom-based fitting model (APFM). HUs were quantified for each organ by manually drawing fixed area-sized regions of interest (ROIs). The mean HUs were collected to obtain the ODs increments following APFM. Regression analysis was applied to find and assess the relationship between the HUs and the OD increments estimated using APFM and that using CT-EXPO. Spearman Coefficient and Wilcoxon Matched Paired t-test were conducted to show statistical correlation and difference between ODs increments using the two methods. Results: A strong significant difference was depicted between S1 and S2 scan series of liver and pancreas using CT-EXPO simulation. Mean HU values for S1 were lower than S2, resulting in statistically significant (p < 0.0001) HU changes. CT-EXPO simulation yielded significantly higher difference in ODs compared to the APFM for liver (p = 0.0455) and pancreas (p = 0.0031). Regression analysis revealed a strong relationship between HU of S1 and S2 and ODs increments using APFM in both organs (R
2
= 0.99), dissimilar to CT-EXPO (R
2 = 0.39 in liver and R
2 = 0.05 in pancreas). Conclusions: Although CT-EXPO allows for estimating ODs accounting for major acquisition scan parameters, it is not a reliable tool to evaluate the impact of contrast enhancement on ODs. On the other hand, the APFM accounts for contrast enhancement accumulation yet only provides relative OD increments, an information of limited clinical use.
Breast cancer is the leading cause of cancer death among women worldwide. Screening mammography is considered the primary imaging modality for the early detection of breast cancer. The radiation dose from mammography increases the patients’ risk of radiation-induced cancer. The mean glandular dose (MGD), or the average glandular dose (AGD), provides an estimate of the absorbed dose of radiation by the glandular tissues of a breast. In this paper, MGD is estimated for the craniocaudal (CC) and mediolateral–oblique (MLO) views using entrance skin dose (ESD), X-ray spectrum information, patient age, breast glandularity, and breast thickness. Moreover, a regression analysis is performed to evaluate the impact of mammography acquisition parameters, age, and breast thickness on the estimated MGD and other machine-produced dose quantities, namely, ESD and organ dose (OD). Furthermore, a correlation study is conducted to evaluate the correlation between the ESD and OD, and the estimated MGD per image view. This retrospective study was applied to a dataset of 2035 mammograms corresponding to a cohort of 486 subjects with an age range of 28–86 years who underwent screening mammography examinations. Linear regression metrics were calculated to evaluate the strength of the correlations. The mean (and range) MGD for the CC view was 0.832 (0.110–3.491) mGy and for the MLO view was 0.995 (0.256–2.949) mGy. All the mammography dose quantities strongly correlated with tube exposure (mAs): ESD (R2 = 0.938 for the CC view and R2 = 0.945 for the MLO view), OD (R2 = 0.969 for the CC view and R2 = 0.983 for the MLO view), and MGD (R2 = 0.980 for the CC view and R2 = 0.972 for the MLO view). Breast thickness showed a better correlation with all the mammography dose quantities than patient age, which showed a poor correlation. Moreover, a strong correlation was found between the calculated MGD and both the ESD (R2 = 0.929 for the CC view and R2 = 0.914 for the MLO view) and OD (R2 = 0.971 for the CC view and R2 = 0.972 for the MLO view). Furthermore, it was found that the MLO scan views yield a slightly higher dose compared to CC scan views. It was also found that the glandular absorbed dose is more dependent on glandularity than size. Despite being more reflective of the dose absorbed by the glandular tissue than OD and ESD, MGD is considered labor-intensive and time-consuming to estimate.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.