The presence of an ionized carboxyl group in the widely used non-steroidal anti-inflammatory (NSAID) drug diclofenac potassium results in a high mobility of diclofenac and in its low sorption under conditions of slow sand filtration or subsoil passage. No diclofenac degradation was detected in pure water or sludge during one month. Tertiary treatments of wastewater indicated that the effective removal of diclofenac was by reverse osmosis, but the removal by activated carbon was less satisfactory. This study presents an efficient method for the removal of diclofenac from water by micelle-clay composites that are positively charged, have a large surface area and include large hydrophobic domains. Adsorption of diclofenac in dispersion by charcoal and a composite micelle (otadecyltrimethylammonium [ODTMA] and clay [montmorillonite]) was investigated. Analysis by the Langmuir isotherm revealed that charcoal had a somewhat larger number of adsorption sites than the composite, but the latter had a significantly larger binding affinity for diclofenac. Filtration experiments on a solution containing 300 ppm diclofenac demonstrated poor removal by activated carbon, in contrast to very efficient removal by micelle-clay filters. In the latter case the weight of removed diclofenac exceeded half that of ODTMA in the filter. Filtration of diclofenac solutions at concentrations of 8 and 80 ppb yielded almost complete removal at flow rates of 30 and 60 mL min(-1). One kilogram of ODTMA in the micelle-clay filter has been estimated to remove more than 99% of diclofenac from a solution of 100 ppb during passage of more than 100 m3.
Removal of Cr(VI) from aqueous solutions under different conditions was investigated using either clay (montmorillonite) or micelle-clay complex, the last obtained by adsorbing critical micelle concentration of octadecyltrimethylammonium ions onto montmorillonite. Batch experiments showed the effects of contact time, adsorbent dosage, and pH on the removal efficiency of Cr(VI) from aqueous solutions. Langmuir adsorption isotherm fitted the experimental data giving significant results. Filtration experiments using columns filled with micelle-clay complex mixed with sand were performed to assess Cr(VI) removal efficiency under continuous flow at different pH values. The micelle-clay complex used in this study was capable of removing Cr(VI) from aqueous solutions without any prior acidification of the sample. Results demonstrated that the removal effectiveness reached nearly 100% when using optimal conditions for both batch and continuous flow techniques.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.