To turn the advantage of energy measurement in x-ray transmission diagnosis into practice, we propose a novel detector for the estimation of x-ray energy distribution. This detector consists of several segment detectors arrayed in the direction of x-ray incidence. Each segment detector measures x-rays as current. With unfolding measured currents, the x-ray energy distribution is obtained. The practical application of this detector was verified by estimating the iodine thickness in an acryl phantom.
A method of internal-detector electron holography is the time-reversed version of photoelectron holography. Using an energy-dispersive x-ray detector, an electron gun, and a computer-controllable sample stage, we measured a multiple-energy hologram of the atomic arrangement around the Ti atom in SrTiO3 by recording the characteristic Ti Kα x-ray spectra for different electron beam angles and wavelengths. A real-space image was obtained by using a fitting-based reconstruction algorithm. 3D atomic images of the elements Sr, Ti, and O in SrTiO3 were clearly visualized. The present work reveals that internal-detector electron holography has great potential for reproducing 3D atomic arrangements, even for light elements.
To turn the advantage of energy measurement in x-ray transmission diagnosis into practice, we propose a novel detector for the estimation of x-ray energy distribution. This detector consists of several segment detectors arrayed in the direction of x-ray incidence. Each segment detector measures x-rays as current. With unfolding measured currents, the x-ray energy distribution is obtained. The practical application of this detector was verified by estimating the iodine thickness in an acryl phantom.
The advantages of energy measurement of x-rays over current measurement in transmission radiography and computed tomography (CT) for detecting iodine contrast media are discussed. Simulation studies on both methods of measurement are carried out, followed by experiments. As data for energy measurement of x-rays, the event ratio of two energy regions with a K-edge of iodine between them is employed. The energy measurement method is immune to beam hardening, while current measurement suffers greatly with changes in x-ray tube voltage and thickness of the body under measurement. This method is useful in interventional radiology and in CT. It will also be useful for detecting other types of contrast medium.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.