JóZef sZubert, sławomir sZubert, woJciech wiecZorek… JóZef sZubert, sławomir sZubert, woJciech wiecZorek, alicJa sZymańska-PasZcZuk, włoDZimierZ Ziółkowski, marietta sZubert wyżsZa sZkoła informatyki i umieJętnoŚci w łoDZi Alternatywna metoda wyznaczania maksymalnego poboru tlenu (vO 2 max) przez organizm człowieka An alternative method of measuring the human maximal oxygen uptake (vO 2 Max) Introduction: One of the main tasks of the physiology of human exercise is the evaluation of physical efficiency. The maximal oxygen uptake (Vo2max) is the best indicator of physical fitness. It allows to widely predict a healthy organism's response to physical strain. It is also considered useful in clinical research for evaluating patients' ability to exercise, as well as monitoring the effects of their treatment or rehabilitation. Every method of measuring the maximal oxygen uptake has its limits and that is why a new, possibly simple, safe and reliable method of measuring Vo2max is constantly sought for.Materials and methods: On the basis of our own and worldwide empirical data, as well as the laws of thermodynamics and fluid mechanics, a new, accurate and safe method of measuring maximal oxygen uptake was developed. The method allows to evaluate Vo2max under various submaximal exercise loads.Results: There is no statistically significant difference between the maximal oxygen uptake values measured using the author's method and those acquired using other researchers' methods.Conclusion: The author's method of measuring maximal oxygen uptake (Vo2max) can be a valid alternative to the currently used methods. WprowadzenieJednym z zadań fizjologii wysiłków fizycznych człowieka jest ocena jego wydolności fizycznej. Może ona służyć określeniu zmian czynnościowych występujących w organizmie człowieka bądź to na skutek treningu, aktywności ruchowej, http://dx.
Podczas przejścia od młodości do wieku starszego maksymalne parametry fizjologiczne serca mężczyzn ulegają zmniejszeniu. Na podstawie światowych danych doświadczalnych, dotyczących badań przekrojowych i longitudinalnych zmian maksymalnych parametrów fizjologicznych serca mężczyzn w procesie starzenia się, stosując analizę matematyczną oraz modelowanie matematyczne i symulację komputerową, opracowano innowacyjne, kompleksowe i wiarygodne metody wyznaczania maksymalnych parametrów fizjologicznych serca mężczyzn: rzutu minutowego serca (COmax), częstości pracy serca (HRmax), objętości wyrzutowej serca (SVmax), różnicy tętniczo-żylnej wysycenia krwi tlenem (AVDmax) oraz pułapu tlenowego (Vo2max). Opracowane metody pozwalają każdy maksymalny parametr fizjologiczny serca dla dużej i przeciętnej wydolności mężczyzn przedstawić: graficznie (za pomocą wykresu), analitycznie (za pomocą równania matematycznego) oraz tabelarycznie. Takie opracowanie maksymalnych parametrów fizjologicznych serca mężczyzn pozwala dla dowolnego wieku i rozpatrywanej wydolności fizycznej wyznaczyć w przekroju poprzecznym wszystkie maksymalne parametry serca: COmax, HRmax, SVmax, AVDmax oraz Vo2max.
JóZef sZubert, sławomir sZubert, woJciech wiecZorek, alicJa sZymańska-PasZcZuk włoDZimierZ Ziółkowski, marietta sZubert wyżsZa sZkoła informatyki i umieJętnoŚci w łoDZi Własna, nieinwazyjna metoda wyznaczania pojemności minutowej (CO) i objętości wyrzutowej (SV) serca dziewcząt i chłopców w wieku 7-9 lat podczas wysiłku fizycznego Our own, non-invasive method of measuring the cardiac output (CO) and stroke volume (SV) in children aged 7-9 during physical exercise Introduction: Cardiac output (CO) determines the cardiovascular system's function and undergoes fluctuations in various physiological and pathological states. All of the currently available CO monitoring methods have their limitations, which is the reason we keep looking for new, possibly simple, cost-effective and safe, but still reliable methods.Materials and methods: Based on both our own and global empiric data and laws of thermodynamics and fluid dynamics, we developed a new, non-invasive and safe method of measuring cardiac output and the stroke volume (SV). The aforementioned method allows us to measure both CO and SV in children undergoing various relative workload exercise.Results: CO and SV values obtained by the author's method do not differ significantly from the values obtained by other researchers using different methods.Conclusions: The developed method is non-invasive, simple, cost-effective, reliable and poses no risk for the examined person's life or health. It can be a viable alternative to the currently used methods.http://dx
Podczas przejścia od młodości do wieku starszego maksymalne parametry fizjologiczne serca kobiet ulegają zmniejszeniu. Na podstawie światowych danych doświadczalnych, dotyczących badań przekrojowych i longitudinalnych zmian maksymalnych parametrów fizjologicznych serca kobiet w procesie starzenia się, stosując analizę matematyczną oraz modelowanie matematyczne i symulację komputerową, opracowano innowacyjne, kompleksowe i wiarygodne metody wyznaczania maksymalnych parametrów fizjologicznych serca kobiet: rzutu minutowego serca (COmax), częstości pracy serca (HRmax), objętości wyrzutowej serca (SVmax), różnicy tętniczo-żylnej wysycenia krwi tlenem (AVDmax) oraz pułapu tlenowego (Vo2max). Opracowane metody pozwalają każdy maksymalny parametr fizjologiczny serca dla dużej i przeciętnej wydolności kobiet przedstawić: graficznie (za pomocą wykresu), analitycznie (za pomocą równania matematycznego) oraz tabelarycznie. Takie opracowanie maksymalnych parametrów fizjologicznych serca kobiet pozwala dla dowolnego wieku i rozpatrywanej wydolności fizycznej wyznaczyć w przekroju poprzecznym wszystkie maksymalne parametry serca: COmax, HRmax, SVmax, AVDmax oraz Vo2max.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.