BACKGROUND Wrong blood in tube (WBIT) errors are a preventable cause of ABO‐mismatched RBC transfusions. Electronic patient identification systems (e.g., scanning a patient's wristband barcode before pretransfusion sample collection) are thought to reduce WBIT errors, but the effectiveness of these systems is unclear. STUDY DESIGN AND METHODS Part 1: Using retrospective data, we compared pretransfusion sample WBIT rates at hospitals using manual patient identification (n = 16 sites; >1.6 million samples) with WBIT rates at hospitals using electronic patient identification for some or all sample collections (n = 4 sites; >0.5 million samples). Also, we compared WBIT rates after implementation of electronic patient identification with preimplementation WBIT rates. Causes and frequencies of WBIT errors were evaluated at each site. Part 2: Transfusion service laboratories (n = 18) prospectively typed mislabeled (rejected) samples (n = 2844) to determine WBIT rates among samples with minor labeling errors. RESULTS Part 1: The overall unadjusted WBIT rate at sites using manual patient identification was 1:10,110 versus 1:35,806 for sites using electronic identification (p < 0.0001). Correcting for repeat samples and silent WBIT errors yielded overall adjusted WBIT rates of 1:3046 for sites using manual identification and 1:14,606 for sites using electronic identification (p < 0.0001), with wide variation among individual sites. Part 2: The unadjusted WBIT rate among mislabeled (rejected) samples was 1:71 (adjusted WBIT rate, 1:28). CONCLUSION In this study, using electronic patient identification at the time of pretransfusion sample collection was associated with approximately fivefold fewer WBIT errors compared with using manual patient identification. WBIT rates were high among mislabeled (rejected) samples, confirming that rejecting samples with even minor labeling errors helps mitigate the risk of ABO‐incompatible transfusions.
BACKGROUND Transfusion of group O blood to non‐O recipients, or transfusion of D– blood to D+ recipients, can result in shortages of group O or D– blood, respectively. This study investigated RBC utilization patterns at hospitals around the world and explored the context and policies that guide ABO blood group and D type selection practices. STUDY DESIGN AND METHODS This was a retrospective study on transfusion data from the 2013 calendar year. This study included a survey component that asked about hospital RBC selection and transfusion practices and a data collection component where participants submitted information on RBC unit disposition including blood group and D type of unit and recipient. Units administered to recipients of unknown ABO or D group were excluded. RESULTS Thirty‐eight hospitals in 11 countries responded to the survey, 30 of which provided specific RBC unit disposition data. Overall, 11.1% (21,235/191,397) of group O units were transfused to non‐O recipients; 22.6% (8777/38,911) of group O D– RBC units were transfused to O D+ recipients, and 43.2% (16,800/38,911) of group O D– RBC units were transfused to recipients that were not group O D–. Disposition of units and hospital transfusion policy varied within and across hospitals of different sizes, with transfusion of group O D– units to non‐group O D– patients ranging from 0% to 33%. CONCLUSION A significant proportion of group O and D– RBC units were transfused to compatible, nonidentical recipients, although the frequency of this practice varied across sites.
This study is the first to identify and document a statistically significant variability in the chloride concentration of available 5% albumin products. This study has also informed a pilot randomized controlled trial examining the effect of administering high chloride versus low chloride fluids in critically ill patients with sepsis.
Although emergency transfusion of uncross-matched blood is commonly practiced at trauma centres worldwide, with low risk of acute HTR (<1/1000), our well-documented patient case demonstrates the potential for acute HTR with severe complications.
BACKGROUND Typical practice is to transfuse group‐specific plasma units; however, there are situations where group AB plasma (universal donor) is issued to group A, B, or O recipients. If demand for group AB plasma exceeds collections, there is potential for shortage. This project explored the patterns of group AB plasma utilization at hospitals around the world. STUDY DESIGN AND METHODS The study had two phases: a survey that inquired about hospital group AB plasma inventory, policies, and transfusion practices and a retrospective review of 2014 calendar year data where participants submitted information on plasma disposition including ABO group of unit and recipient, transfusion location, and select indications. Recruitment occurred through snowball sampling. Descriptive analyses were performed. RESULTS Survey data were received from 25 centers across 10 countries; of those, 15 participants contributed to the data collection component. These 15 centers transfused a total of 43,369 AB plasma units during the study period. Only 1496 of 5541 (27%) group AB plasma units were transfused to group AB recipients. Transfusion policies, practices, and patterns were variable across sites. CONCLUSION Group AB plasma units are frequently transfused to non‐AB recipients. Whether transfusing 73% of group AB plasma units to non‐AB recipients is the ideal inventory management strategy remains to be determined.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.