A simple, accurate, rapid and sensitive reversed-phase high-performance liquid chromatography (RP-HPLC) method was established for determination of a novel non-vitamin K antagonist oral anticoagulant drug, betrixaban, and its co-administered calcium-channel blocker drug, lercanidipine, in pharmaceutical formulations and biological fluids. The proposed HPLC method was the first chromatographic method applied to estimate this mixture in a short chromatographic run (<6 min), high resolution between betrixaban/lercanidipine (Rs = 7.12) and acceptable values of limit of detection (LOD), limit of quantification (LOQ) and percentage of relative standard deviation (%RSD). The chromatographic separation was performed on a cyano column using a mobile phase composed of acetonitrile:methanol:water (35:35:30, v/v/v) containing 0.2% orthophosphoric acid adjusted to pH 3.2 by triethylamine, programmed with a flow rate of 1 mL/min with UV detection at 240 nm. The proposed method showed linearity over the concentration ranges of (0.20–20.0 μg/mL) and (0.25–25.0 μg/mL) for betrixaban and lercanidipine, respectively. All validation parameters met the acceptance criteria according to ICH guidelines in terms of linearity, LOD, LOQ, accuracy, precision, robustness, specificity and system suitability. The method was applied to assay the studied analytes in their pharmaceutical formulations with high % recovery (98–102%) and low %RSD (<1.5). Furthermore, the proposed method was successfully applied for the determination of betrixaban in spiked human plasma.
Background:The first highly sensitive, rapid and specific green microemulsion liquid
chromatographic (MELC) method was established for the simultaneous estimation of fluticasone propionate
(FLU) and azelastine HCl (AZL) in the presence of their pharmaceutical dosage form additives
(phenylethyl alcohol (PEA) and benzalkonium chloride (BNZ)).Methods:The separation was performed on a C18 column using (o/w) microemulsion as a mobile
phase which contains 0.2 M sodium dodecyl sulphate (SDS) as surfactant, 10% butanol as cosurfactant,
1% n-octanol as internal phase and 0.3% triethylamine (TEA) adjusted at pH 6 by 0.02 M
phosphoric acid; with UV detection at 220 nm and programmed with flow rate of 1 mL/min.Results:The validation characteristics e.g. linearity, lower limit of quantification (LOQ), lower limit
of detection (LOD), accuracy, precision, robustness and specificity were investigated. The proposed
method showed linearity over the concentration range of (0.5-25 µg/mL) and (0.1-25 µg/mL) for FLU
and AZL, respectively. Besides that, the method was adopted in a short chromatographic run with satisfactory
resolution factors of (2.39, 3.78 and 6.74 between PEA/FLU, FLU/AZL and AZL/BNZ), respectively.
The performed method was efficiently applied to pharmaceutical nasal spray with (mean
recoveries ± SD) (99.80 ± 0.97) and (100.26 ± 0.96) for FLU and AZL, respectively.Conclusion:The suggested method was based on simultaneous determination of FLU and AZL in the
presence of PEA and BNZ in pure form, laboratory synthetic mixture and its combined pharmaceutical
dosage form using green MELC technique with UV detection. The proposed method appeared to
be superior to the reported ones of being more sensitive and specific, as well as the separation was
achieved with good performance in a relatively short analysis time (less than 7.5 min). Highly acceptable
values of LOD and % RSD make this method superior to be used in quality control laboratories
with of HPLC technique.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.