A collaborative study was conducted to validate an analytical method for the determination of ochratoxin A (OTA) in licorice (root powder) and licorice extracts (paste and powder). Contents of OTA ranged from 26 to 141 microg/kg and from 8 to 52 microg/kg for licorice extracts and root material, respectively. For the analysis, a test portion is extracted with a mixture of methanol and aqueous sodium bicarbonate solution. The extract is filtered and diluted with phosphate-buffered saline; and OTA is purified with an immunoaffinity column containing antibodies specific to OTA. The purified extract is dried, reconstituted, and quantified by HPLC with fluorescence detection. Twenty laboratories from 13 European Union member states, Uruguay, Turkey, and the United States of America participated in this study. The study was evaluated according to internationally accepted guidelines. The method performance characteristics can be summarized as follows: over a working range of 7.7 to 141 microg/kg OTA, the mean recoveries were 87% for licorice root and 84-88% for licorice extracts; and the RSDs for reproducibility ranged from 10 to 17% and from 11 to 22% in licorice extracts and licorice root, respectively. The method was found to be fit-for-purpose and to fulfill legal requirements as set in EC Regulation No. 401/2006.
An interlaboratory study was conducted for the determination of deoxynivalenol in baby food and animal feed by high-performance liquid chromatography with UV detection. The study included 14 participants representing a cross section of industry, official food control, and research facilities. Mean recoveries reported ranged from 89% (at 120 g/kg) to 85% (at 240 g/kg) for baby food and from 100% (at 200 g/kg) to 93% (at 400 g/kg) for animal feed. On the basis of the results for spiked samples (blind duplicates at 2 levels), as well as those for naturally contaminated samples (blind duplicates at 3 levels), the relative standard deviation for repeatability (RSDr) in analyses of baby food ranged from 6.4 to 14.0% and in analyses of animal feed, from 6.1 to 16.5%. The relative standard deviation for reproducibility (RSDR) in analyses of baby food ranged from 9.4 to 19.5% and in analyses of animal feed, from 10.5 to 25.2%. The HorRat values ranged from 0.4 to 1.0 and from 0.7 to 1.3, for baby food and animal feed, respectively. The method showed acceptable performance for within-laboratory and between-laboratory precision for each matrix, as required by European legislation.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.