The success rates of traditional endocardial ablation techniques for managing atrial fibrillation remain modest. Recently, the performance of posterior wall ablation in conjunction with pulmonary vein (PV) isolation (PVI) has been reported to increase the chance of success following endocardial ablation. We report a systematic approach for the isolation of the PVs and ablation of the left atrial roof and posterior wall using a cryoballoon guided by the novel Navik 3D™ mapping system (APN Health LLC, Waukesha, WI, USA) and offer preliminary data including procedure, fluoroscopy, and cryoablation times for review. Patients (n = 52) aged 63 years ± 10 years with paroxysmal (n = 42), persistent (n = 11), or chronic (n = 2) atrial fibrillation underwent cryoballoon ablation for PVI and/or the left atrial roof, posterior wall, anterior ganglion plexi (GP), or mitral isthmus line. Lesions were accurately delivered to the PVs, left atrial roof, posterior wall, anterior GP, or mitral isthmus line as appropriate. Acute PVI was achieved in 98% of all patients, and eight (15%) required direct current cardioversion to restore sinus rhythm at the end of the procedure. The mean ± standard deviation procedure, fluoroscopy, and cryoballoon ablation times were 149 minutes ± 39 minutes, 33 minutes ± 30 minutes, and 41 minutes ± 14 minutes, respectively. The Navik 3D™ mapping system is believed to be the only available mapping system that allows for the visualization and location of the cryoballoon in three dimensions, enabling the operator to deliver contiguous, overlapping lesions on the roof and posterior wall of the left atrium. It also facilitates precise measurement of the distance between the esophageal temperature probe and the cryoballoon, thereby helping to avoid freezing damage to the esophagus.
Purpose: Multiple technologies are being utilized to improve real‐time tumor tracking. To date, there have not been methods to prospectively compare different technologies with realistic tumor trajectories. We evaluated the capabilities of the Calypso® Medical 4D Localization System (Calypso Medical, Seattle, WA) and Varian Trilogy System (Varian Medical Systems, Palo Alto, CA) fluoroscopy in tracking dynamic objects. Method and Materials: Initially, a quality assurance fixture containing three implantable transponders was moved by an in‐house developed 4D phantom through an ellipse and a non‐uniform human lung tumor path modeled with CT imaging and spirometry. Subsequently, three transponders that had been implanted in a canine lung were tracked. In both experiments, the transponders were fluoroscopically imaged on a Trilogy system while simultaneously being tracked by the Calypso® 4D localization system. The fluoroscopic images were recorded and later analyzed using a custom‐written (MATLAB) image processing program to determine the transponder projection positions with respect to time. The trajectories derived from the fluoroscopic images were synchronized with and compared to the Calypso System position data. Results: The root mean square (RMS) position differences were less than 0.03 mm for all tested measurement system combinations. While both were small, the Calypso System RMS error was slightly lower than that of the fluoroscopy when compared against the 4D phantom positions. Of the three trajectories, the RMS error between imaging modalities was largest for the patient trajectory and smallest for the ellipses. Conclusion: This work indicates that both tracking methods provide excellent positioning accuracy. Although the accuracy discrepancy between the two systems is negligible, the Calypso® System also offers the ability to localize in three dimensions and has the advantage of being able to track a target continuously without the use of ionizing radiation. Conflict of Interest: Supported in part by Calypso Medical Technologies, Inc.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.