Catheter related blood stream infection is an ever present hazard for those patients requiring venous access and particularly for those requiring long term medication. The implementation of more rigorous care bundles and greater adherence to aseptic techniques have yielded substantial reductions in infection rates but the latter is still far from acceptable and continues to place a heavy burden on patients and healthcare providers. While advances in engineering design and the arrival of functional materials hold considerable promise for the development of a new generation of catheters, many challenges remain. The aim of this review is to identify the issues that presently impact catheter performance and provide a critical evaluation of the design considerations that are emerging in the pursuit of these new catheter systems.
The combination of paraffin wax and O,O′-bis(2-aminopropyl) polypropylene glycol–block–polyethylene glycol–block–polypropylene glycol was used as a phase-change material (PCM) for the controlled delivery of curcumin. The PCM was combined with a graphene-based heater derived from the laser scribing of polyimide film. This assembly provides a new approach to a smart patch through which release can be electronically controlled, allowing repetitive dosing. Rather than relying on passive diffusion, delivery is induced and terminated through the controlled heating of the PCM with transfer only occurring when the PCM transitions from solid to liquid. The material properties of the device and release characteristics of the strategy under repetitive dosing are critically assessed. The delivery yield of curcumin was found to be 3.5 µg (4.5 µg/cm2) per 3 min thermal cycle.
Conductive microneedle patches based on carbon nanoparticle composites in which cellulose acetate phthalate (CAP) or polystyrene (PS) acted as a binder were investigated. The electrochemical properties of the composite system were assessed using ferrocyanide as a redox probe and compared to screen printed carbon electrodes. Preliminary investigations of biodegradability were conducted with the influence of soil interment assessed by electron microscopy. While the PS microneedles exhibited no breakdown, the CAP systems were found to be substantially degraded after 1 week with complete removal of the needle tips and hence piercing capability.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.