Roche-Seruendo, LE, García-Pinillos, F, Haicaguerre, J, Bataller-Cervero, AV, Soto-Hermoso, VM, and Latorre-Román, PÁ. Lack of influence of muscular performance parameters on spatiotemporal adaptations with increased running velocity. J Strength Cond Res 32(2): 409-415, 2018-This study aimed to analyze the influence of muscular performance parameters on spatiotemporal gait characteristics during running when gradually increasing speed. Fifty-one recreationally trained male endurance runners (age, 28 ± 8 years) voluntarily participated in this study. Subjects performed a battery of jumping tests (squat jump, countermovement jump, and 20-cm drop jump), and after that, the subjects performed an incremental running test (10-20 km·h) on a motorized treadmill. Spatiotemporal parameters were measured using the OptoGait system. Cluster k-means analysis grouped subjects according to the jumping test performance, by obtaining a group of good jumpers (n = 19) and a group of bad jumpers (n = 32). With increased running velocity, contact time was shorter and flight time and step length were longer, whereas cadence and stride angle were greater (p < 0.001). No significant differences between groups (p ≥ 0.05) were found at any running speed. The results obtained indicate that increased running velocity produced no differences in spatiotemporal adaptations between those runners with good jumping ability and those with poor jumping ability. Based on that, it seems that muscular performance parameters do not play a key role in spatiotemporal adaptations experienced by recreational endurance runners with increased velocity. However, taken into consideration the well-known relationship between running performance and neuromuscular performance, the authors suggest that muscular performance parameters would be much more determinant in the presence of fatigue (exhausted condition) or in the case of considering other variables such as running economy or kinetic.
BACKGROUND: Exercise has been demonstrated as effective for the treatment of low back pain (LBP) in workers. OBJECTIVE: The purpose of this study was to investigate whether an exercise program adapted to the characteristics of the workplace is a useful supplement to general exercise recommendations in assembly line workers with chronic LBP. METHODS: Workers were randomly assigned to intervention group-adapted exercises plus general exercise recommendations (n = 10), and control group-general exercise recommendations (n = 8). Both received 8-week exercise program through a mobile application (APP) to manage the intervention. Outcome was based on lumbar disability (Oswestry Disability Index), interference and lumbar pain intensity (Brief Pain Inventory), and kinematic parameters. RESULTS: Significant differences were obtained for the intervention group in the “pain interference” variable, in the “mood” and “enjoyment” sub-variables, as well as in “flexion angle” variable. For the control group, significant differences occurred in the “pain intensity” variable. Adapted exercise plus general recommendations seems more effective than the general recommendations for the improvement of lumbar flexion. CONCLUSIONS: An adapted exercise program for assembly line workers with chronic LBP could be an effective treatment. Future studies are recommended with a larger sample size and with an exhaustive control of the exercise adherence are required to confirm the findings of this pilot study.
Our purpose was to assess the 10 Hz Viper GPS devices’ validity and reliability (STATSport) in both instantaneous and mean speed measuring in accelerations and decelerations in straight-line running conditions. Eight amateur team sport players participated in the study, performing firstly 21 x 40 m sprints at submaximal incremental speed, and secondly 21 x 40 m sprints, with the first stage consisting of submaximal incremental speed, and the second stage of subsequent submaximal decreasing speed. Criteria systems used to evaluate the GPS validity were a radar gun for instantaneous speed, and timing-gates for mean speed. Reliability was measured with two GPS devices carried by the same athlete, running 10 x (20 m + 20 m) sprints with a 180º change of direction and a 10 s inter-set rest interval. Results showed an agreement between GPS devices and the criteria systems measuring instantaneous speed (r = 0.98; standardized mean bias (SMB) = -0.07; standard typical error (STE) = 0.22) and mean speed (r = 0.99; SMB = 0.38; STE = 0.17). The reliability study presented a nearly perfect correlation between devices, a trivial SMB and a small STE (r = 0.97; SMB = 0.04; STE = 0.23). 10 Hz GPS devices are an adequate solution to monitor straight-line running speed in acceleration and deceleration conditions, but we would like to draw attention to the small errors and bias detected, such as the speed overestimation compared with timing gates.
The purpose of this study was to assess the effect of a six week exercise program to reduce the muscle tone of the trapezius and musculoskeletal discomfort (MED) of office workers. Twenty-six workers performed an exercise program based on: (1) stretching of cervical and/or dorsal region; (2) joint mobility of shoulders and rachis; (3) strengthening deep stabilizer and core muscles; and (4) scapula stabilizing exercises. A Myoton device was used to evaluate trapezius tone and the Cornell Musculoskeletal Discomfort Questionnaire was used to assess changes in MED at three points of evaluation: at the beginning (Pre_1) and at the end of the workday (Post_1), and after the training program (Pre_2). The Wilcoxon test and Cohen’s d were performed to examine differences and effect sizes between evaluations. Main results show that trapezius tone remained constant during the workday, but decreased in the dominant upper trapezius (p = 0.003, ES = −0.60) and increased in the non-dominant middle trapezius (p = 0.016, ES = 0.45) after the exercise program, which eliminated significant muscle asymmetries. MED significantly decreased in the neck (p = 0.027, ES = −0.60) and upper back (p = 0.046, ES = −0.67). In conclusion, MED appears to improve in office workers after a six week training program, which may be explained by a decrease in trapezius tone and increase in the left middle trapezius tone.
Low back pain (LBP) is a common problem in manufacturing workers. Several strategies have been proposed in order to reduce the pain and/or improve functionality. Among them, lumbar supports are a common solution prescribed for lumbar pain relief. Most of the studies in the literature only consider subjective sensations of the workers for evaluation assessment. This study applies biomechanical tests (a flexion-relaxation test and a functional movement evaluation test) to analyse the effectiveness of flexible lumbar supports in functionality and disability versus placebo intervention, consisting of kinesiotape placed on the low back without any stress. 28 workers participated in the study, randomised in control and intervention groups with a two months’ intervention. None of the biomechanical tests showed statistical differences in between-groups pre-post changes. No benefits of wearing a flexible lumbar support during the workday have been found in these assembly-line workers versus placebo intervention.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.