García-Pinillos, F, Roche-Seruendo, LE, Marcen-Cinca, N, Marco-Contreras, LA, and Latorre-Román, PA. Absolute reliability and concurrent validity of the Stryd system for the assessment of running stride kinematics at different velocities. J Strength Cond Res XX(X): 000-000, 2018-This study aimed to determine the absolute reliability and to evaluate the concurrent validity of the Stryd system for measuring spatiotemporal variables during running at different velocities (8-20 km·h) by comparing data with another widely used device (the OptoGait system). Eighteen trained male endurance runners performed an incremental running test (8-20 km·h with 3-minute stages) on a treadmill. Spatiotemporal parameters (contact time [CT], flight time [FT], step length [SL], and step frequency [SF]) were measured using 2 different devices (Stryd and OptoGait systems). The Stryd system showed a coefficient of variation (CV) <3%, except for FT (3.7-11.6%). The OptoGait achieved CV <4%, except for FT (6.0-30.6%). Pearson correlation analysis showed large correlations for CT and FT, and almost perfect for SL and SF over the entire protocol. The intraclass correlation coefficients partially support those results. Paired t-tests showed that CT was underestimated (p < 0.05, effect size [ES] > 0.7; ∼4-8%), FT overestimated (p < 0.05, ES > 0.7; ∼7-65%), whereas SL and SF were very similar between systems (ES < 0.1, with differences <1%). The Stryd is a practical portable device that is reliable for measuring CT, FT, SL, and SF during running. It provides accurate SL and SF measures but underestimates CT (0.5-8%) and overestimates FT (3-67%) compared with a photocell-based system.
The mDurance® system is an innovative digital tool that combines wearable surface electromyography (sEMG), mobile computing and cloud analysis to streamline and automatize the assessment of muscle activity. The tool is particularly devised to support clinicians and sport professionals in their daily routines, as an assessment tool in the prevention, monitoring rehabilitation and training field. This study aimed at determining the validity of the mDurance system for measuring muscle activity by comparing sEMG output with a reference sEMG system, the Delsys® system. Fifteen participants were tested during isokinetic knee extensions at three different speeds (60, 180, and 300 deg/s), for two muscles (rectus femoris [RF] and vastus lateralis [VL]) and two different electrodes locations (proximal and distal placement). The maximum voluntary isometric contraction was carried out for the normalization of the signal, followed by dynamic isokinetic knee extensions for each speed. The sEMG output for both systems was obtained from the raw sEMG signal following mDurance's processing and filtering. Mean, median, first quartile, third quartile and 90th percentile was calculated from the sEMG amplitude signals for each system. The results show an almost perfect ICC relationship for the VL (ICC > 0.81) and substantial to almost perfect for the RF (ICC > 0.762) for all variables and speeds. The Bland-Altman plots revealed heteroscedasticity of error for mean, quartile 3 and 90th percentile (60 and 300 deg/s) for RF and at mean and 90th percentile for VL (300 deg/s). In conclusion, the results indicate that the mDurance® sEMG system is a valid tool to measure muscle activity during dynamic contractions over a range of speeds. This innovative system provides more time for clinicians (e.g., interpretation patients' pathologies) and sport trainers (e.g., advising athletes), thanks to automatic processing and filtering of the raw sEMG signal and generation of muscle activity reports in real-time.
This study aimed to evaluate the concurrent validity of two different inertial measurement units for measuring spatiotemporal parameters during running on a treadmill, by comparing data with a high-speed video analysis (VA) at 1,000 Hz. Forty-nine endurance runners performed a running protocol on a treadmill at comfortable velocity (i.e., 3.25 ± 0.36 m.s-1). Those wearable devices (i.e., Stryd™ and RunScribe™ systems) were compared to a high-speed VA, as a reference system for measuring spatiotemporal parameters (i.e. contact time [CT], flight time [FT], step frequency [SF] and step length [SL]) during running at comfortable velocity. The pairwise comparison revealed that the Stryd™ system underestimated CT (5.2%, p < 0.001) and overestimated FT (15.1%, p < 0.001) compared to the VA; whereas the RunScribe™ system underestimated CT (2.3%, p = 0.009). No significant differences were observed in SF and SL between the wearable devices and VA. The intra class correlation coefficient (ICC) revealed an almost perfect association between both systems and high-speed VA (ICC > 0.81). The Bland-Altman plots revealed heteroscedasticity of error (r2 = 0.166) for the CT from the Stryd™ system, whereas no heteroscedasticity of error (r2 < 0.1) was revealed in the rest of parameters. In conclusion, the results obtained suggest that both foot pods are valid tools for measuring spatiotemporal parameters during running on a treadmill at comfortable velocity. If the limits of agreement of both systems are considered in respect to high-speed VA, the RunScribe™ seems to be a more accurate system for measuring temporal parameters and SL than the Stryd™ system.
This study aimed to examine the effect of running velocity on spatiotemporal parameters and lower-body stiffness of endurance runners, and the influence of the performance level on those adaptations. Twenty-two male runners (novice [NR], n = 12, and elite runners [ER], n = 10) performed an incremental running test with a total of 5 different running velocities (10, 12, 14, 16, 18 km/h). Each condition lasted 1 min (30 s acclimatization period, and 30 s recording period). Spatiotemporal parameters were measured using the OptoGait system. Vertical (Kvert) and leg (Kleg) stiffness were calculated according to the sine-wave method. A repeated measures ANOVA (2 x 5, group x velocities) revealed significant adaptations (p < 0.05) to increased velocity in all spatiotemporal parameters and Kvert in both NR and ER. ER showed a greater flight time (FT) and step angle (at 18 km/h) (p < 0.05), longer step length (SL) and lower step frequency (SF) (p < 0.05), whereas no between-group differences were found in contact time (CT) nor in the sub-phases during CT at any speed (p ≥ 0.05). ER also showed lower Kvert values at every running velocity (p < 0.05), and no differences in Kleg (p ≥ 0.05). In conclusion, lower SF and Kvert and, thereby, longer FT and SL, seem to be the main spatiotemporal characteristics of high-level runners compared to their low-level counterparts.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.