Background
Regional anesthesia has several advantages over general anesthesia but requires accurate needle placement to be effective. To achieve accurate placement, a needle equipped with optical fibers that allows tissue discrimination at the needle tip based on optical spectroscopy is proposed. This study investigates the sensitivity and specificity with which this optical needle can discriminate nerves from the surrounding tissues making use of different classification methods.MethodsDiffuse reflectance spectra were acquired from 1563 different locations from 19 human cadavers in the wavelength range of 400–1710 nm; measured tissue types included fascicular tissue of the nerve, muscle, sliding fat and subcutaneous fat. Physiological parameters of the tissues were derived from the measured spectra and part of the data was directly compared to histology. Various classification methods were then applied to the derived parameter dataset to determine the accuracy with which fascicular tissue of the nerve can be discriminated from the surrounding tissues.ResultsFrom the parameters determined from the measured spectra of the various tissues surrounding the nerve, fat content, blood content, beta-carotene content and scattering were most distinctive when comparing fascicular and non-fascicular tissue. Support Vector Machine classification with a combination of feature selections performed best in discriminating fascicular nerve tissue from the surrounding tissues with a sensitivity and specificity around 90 %.ConclusionsThis study showed that spectral tissue sensing, based on diffuse reflectance spectroscopy at the needle tip, is a promising technique to discriminate fascicular tissue of the nerve from the surrounding tissues. The technique may therefore improve accurate needle placement near the nerve which is necessary for effective nerve blocks in regional anesthesia.
The results indicate that the spectroscopic information provided by the needle stylet could potentially allow for reliable identification of transitions from subcutaneous fat to skeletal muscle and from the muscle to the nerve target region during peripheral nerve blocks.
PurposeThoracic paravertebral block (TPVB) may be an alternative to thoracic epidural analgesia. A detailed knowledge of the anatomy of the TPV-space (TPVS), content and adnexa is essential in understanding the clinical consequences of TPVB. The exploration of the posterior TPVS accessibility in this study allows (1) determination of the anatomical boundaries, content and adnexa, (2) description of an ultrasound-guided spread of low and high viscous liquid.MethodsIn two formalin-fixed specimens, stratification of the several layers and the 3D-architecture of the TPVS were dissected, observed and photographed. In a third unembalmed specimen, ultrasound-guided posterolateral injections at several levels of the TPVS were performed with different fluids.ResultsTPVS communicated with all surrounding spaces including the segmental dorsal intercostal compartments (SDICs) and the prevertebral space. TPVS transitions to the SDICs were wide, whereas the SDICs showed narrowed transitions to the lateral intercostal spaces at the costal angle. Internal subdivision of the TPVS in a subendothoracic and an extra-pleural compartment by the endothoracic fascia was not observed. Caudally injected fluids spread posteriorly to the costodiaphragmatic recess, showing segmental intercostal and slight prevertebral spread.ConclusionsOur detailed anatomical study shows that TPVS is a potential space continuous with the SDICs. The separation of the TPVS in a subendothoracic and an extra-pleural compartment by the endothoracic fascia was not observed. Based on the ultrasound-guided liquid spread we conclude that the use of a more lateral approach might increase the probability of intravascular puncture or catheter position.
ETV should be considered as initial treatment and carries low morbidity in these infants. As the immune system rapidly matures, postponing shunt implantation for several months or even weeks would make an ETV procedure worthwhile. On the other hand, as success probability rapidly increases 4 months after birth, re-ETV should always be considered first.
The results from this study suggest that optical spectroscopy has the potential to detect intravascular needle placement, which may in turn increase the safety of nerve blocks.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.